Time Efficient 3D Radial UTE Sampling with Fully Automatic Delay Compensation on a Clinical 3T MR Scanner
نویسندگان
چکیده
منابع مشابه
Time Efficient 3D Radial UTE Sampling with Fully Automatic Delay Compensation on a Clinical 3T MR Scanner
This work's aim was to minimize the acquisition time of a radial 3D ultra-short echo-time (UTE) sequence and to provide fully automated, gradient delay compensated, and therefore artifact free, reconstruction. The radial 3D UTE sequence (echo time 60 μs) was implemented as single echo acquisition with center-out readouts and improved time efficient spoiling on a clinical 3T scanner without hard...
متن کاملFast 3D UTE Imaging of Knee Connective Tissues on a Clinical 3T Scanner
INTRODUCTION Connective tissues in human knee joint, such as articular cartilage, menisci, or ligaments, have short transverse relaxation time components (T2 ~5ms) due to their collagen-rich micro-structures (1). To image those short-T2 components with minimum signal loss, special pulse sequences capable of ultra-short echo time (UTE) are desired. A number of UTE sequences have been developed i...
متن کاملRapid in Vivo Adc Mapping of Hyperpolarized C Metabolites on a Clinical 3t Mr Scanner
Introduction: Apparent diffusion coefficient (ADC) maps of water have become useful for prostate cancer identification and characterization. Differences in local water mobility create contrast in these images, which in turn give an indication of the local tissue microstructure. The growing field of hyperpolarized C has also proven to be useful in identifying tumors by measuring the real-time me...
متن کاملQuantitative proton MRI and MRS of the rat brain with a 3T clinical MR scanner.
OBJECTIVE To demonstrate the capability of a clinical 3T human scanner in performing quantitative MR experiments in the rat brain. MATERIAL AND METHODS In vivo, measurements on eight Wistar rats were performed. Longitudinal relaxation time (T1) and transverse relaxation time (T2) measurements were set up at a spatial resolution of 0.3×0.3×1mm(3). Diffusion-weighted imaging was also applied an...
متن کاملA New Method for Time-Delay Compensation in Control Systems
In this paper a new method is introduced and investigated for removing the destabilizing effects of time-delay parameter in control loops. The concept of the method is taken from the knowledge concerning the dynamic behaviour of irrational transfer functions (Ir-TF), which is discussed and investigated elswhere in frequency response domain and is explained briefly here. Ir-TFs, which are we...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
ژورنال
عنوان ژورنال: PLOS ONE
سال: 2016
ISSN: 1932-6203
DOI: 10.1371/journal.pone.0150371