Time-cost analysis of a quantum key distribution system clocked at 100 MHz
نویسندگان
چکیده
منابع مشابه
Time-cost analysis of a quantum key distribution system clocked at 100 MHz.
We describe the realization of a quantum key distribution (QKD) system clocked at 100 MHz. The system includes classical postprocessing implemented via software, and is operated over a 12 km standard telecommunication dark fiber in a real-world environment. A time-cost analysis of the sifted, error-corrected, and secret key rates relative to the raw key rate is presented, and the scalability of...
متن کاملQuantum key distribution system clocked at 2 GHz.
An improved quantum key distribution test system operating at clock rates of up to 2GHz using a specially adapted commercially-available silicon single-photon counting module is presented. The use of an enhanced detector has improved the fiber-based quantum key distribution test system performance in terms of transmission distance and quantum bit error rate.
متن کاملTowards a Short-range Free-space GHz-clocked Quantum Key Distribution System
A free-space quantum key distribution system that operates at a wavelength of 850 nm is presented. The system is designed to implement the B92 protocol at high transmission rates between two locations in urban areas. OCIS codes: (270.5568) Quantum cryptography; (060.2605) Free-space optical communication
متن کاملLow Cost and Compact Quantum Key Distribution
We present the design of a novel free-space quantum cryptography system, complete with purpose-built software, that can operate in daylight conditions. The transmitter and receiver modules are built using inexpensive off-the-shelf components. Both modules are compact allowing the generation of renewed shared secrets on demand over a short range of a few metres. An analysis of the software is sh...
متن کامل25 MHz clock continuous-variable quantum key distribution system over 50 km fiber channel
In this paper, a practical continuous-variable quantum key distribution system is developed and it runs in the real-world conditions with 25 MHz clock rate. To reach high-rate, we have employed a homodyne detector with maximal bandwidth to 300 MHz and an optimal high-efficiency error reconciliation algorithm with processing speed up to 25 Mbps. To optimize the stability of the system, several k...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
ژورنال
عنوان ژورنال: Optics Express
سال: 2011
ISSN: 1094-4087
DOI: 10.1364/oe.19.017729