“Time-building specific” seismic vulnerability assessment of a hospital RC building using field monitoring data
نویسندگان
چکیده
منابع مشابه
Assessment of an RC existing hospital building with special moment frame using fragility curve
In this study, an existing hospital structure has been evaluated with incremental dynamic analysis (IDA). This building is accommodated in Karaj with soil type II. At first, two 2-D frames along X, Y direction are selected. Then, five performance levels are determined according to “Rehabilitation Code for Existing Buildings (Publication No. 360) including Immediate Operational (IO), Limited Dam...
متن کاملSurveying and Monitoring for Vulnerability Assessment of an Ancient Building
This paper examines how surveying and monitoring improve our knowledge about ancient buildings, allow the interpretation of their structural response and help in the search for the best solutions for their conservation. The case study of Palazzo del Capitano in Mantua (Italy) is analyzed. In particular, the attention is focused on the use of a Terrestrial Laser Scanner (TLS) for surveying and m...
متن کاملSeismic Vulnerability Assessment of Existing Rc Buildings in Gis Environment
With rapid population growth over the past 30 years and no significance seismic activity during this period, the unchecked development of the built environment in Bangladesh has been resulted in little resilience to earthquake. Identifying buildings due to this unchecked development that has high vulnerability is of critical importance both for reliable loss estimation as a result of an expecte...
متن کاملOPTIMAL PERFORMANCE-BASED SEISMIC DESIGN OF COMPOSITE BUILDING FRAMES WITH RC COLUMNS AND STEEL BEAMS
Composite RCS building frames integrate reinforced concrete columns with structural steel beams to provide an efficient solution for the design and construction of earthquake-resisting structures. In this paper, an optimization framework is developed for performance-based seismic design of planar RCS moment resisting frames. The objective functions are defined as minimizing the construction cos...
متن کاملSeismic Mitigation of Building Frames using Magnetorheological Damper (TECHNICAL NOTE)
The present study focusses on the damping force control of shear mode magnetorheological (MR) damper for seismic mitigations. Therefore, the semi-active MR damper which can control the vibration is analyzed both experimentally and numerically. Carbonyl iron is used as the magnetic particle and Castrol Magnetec oil as carrier fluid throughout the study. MR damper is designed and fabricated, and ...