Tidal volume transmission during non-synchronized nasal intermittent positive pressure ventilation via RAM® cannula
نویسندگان
چکیده
منابع مشابه
Inspiratory time and tidal volume during intermittent positive pressure ventilation.
We measured the tidal volume achieved during intermittent positive pressure ventilation using various inspiratory times with a minimum of 0.2 seconds. Results indicate that tidal volume shows no reduction with inspiratory times down to 0.4 seconds. An inspiratory time of 0.3 seconds, however, is likely to reduce tidal volume by 8%, and at 0.2 seconds a 22% fall may be anticipated.
متن کاملDeterminants of effective ventilation during nasal intermittent positive pressure ventilation.
Our aim was to verify in healthy subjects submitted to nasal intermittent positive pressure ventilation (nIPPV) with a volumetric ventilator on controlled mode, whether changes in ventilator settings (delivered tidal volume (VT), respiratory frequency (fR) and inspiratory flow (V'I) could influence effective minute ventilation (V'E), thus allowing identification of the settings resulting in the...
متن کاملHigh-flow nasal cannula versus noninvasive positive pressure ventilation in acute respiratory failure: interaction between PaO2/FiO2 and tidal volume
We read with interest the systematic review by Zhao et al. [1] comparing the effect of the high-flow nasal cannula (HFNC) and noninvasive positive pressure ventilation (NIPPV) therapies in acute respiratory failure. Coincidentally, a similar review [2] was also published in Chest recently in which the cohort studies were also included. Both of these two reviews reported that, compared to HFNC, ...
متن کاملA Comparison between Nasal Intermittent Positive Pressure Ventilation and Nasal Continuous Positive Airway Pressure Ventilation in the Treatment of Neonatal Respiratory Distress Syndrome
Background: Nasal intermittent positive pressure ventilation (NIPPV) is a non-invasive ventilatory mode, which delivers mechanical ventilation via nasal tubes or prongs. The present study was conducted to compare the efficacy of NIPPV and nasal continuous positive airway pressure ventilation (NCPAP) in reducing the need for intubation in preterm infants with respiratory distress syndrome (RDS)....
متن کاملFlow-Synchronized Nasal Intermittent Positive Pressure Ventilation for Infants <32 Weeks' Gestation with Respiratory Distress Syndrome
Aim. To evaluate whether synchronized-NIPPV (SNIPPV) used after the INSURE procedure can reduce mechanical ventilation (MV) need in preterm infants with RDS more effectively than NCPAP and to compare the clinical course and the incidence of short-term outcomes of infants managed with SNIPPV or NCPAP. Methods. Chart data of inborn infants <32 weeks undergoing INSURE approach in the period Januar...