Tibial component with and without stem extension in a trabecular metal cone construct

نویسندگان
چکیده

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Trabecular metal tibial knee component still stable at 10 years

Background and purpose - Total knee replacement (TKR) in younger patients using cemented components has shown inferior results, mainly due to aseptic loosening. Excellent clinical results have been reported with components made of trabecular metal (TM). In a previous report, we have shown stabilization of the TM tibial implants for up to 5 years. In this study, we compared the clinical and RSA ...

متن کامل

A trabecular metal tibial component in total knee replacement in patients younger than 60 years: a two-year radiostereophotogrammetric analysis.

We compared the performance of uncemented trabecular metal tibial components in total knee replacement with that of cemented tibial components in patients younger than 60 years over two years using radiostereophotogrammetric analysis (RSA). A total of 22 consecutive patients (mean age 53 years, 33 to 59, 26 knees) received an uncemented NexGen trabecular metal cruciate-retaining monobloc tibial...

متن کامل

Augmentation of tibial plateau fractures with Trabecular Metal™: a biomechanical study

BACKGROUND Restoration and maintenance of the plateau surface are the key points in the treatment of tibial plateau fractures. Any deformity of the articular surface jeopardizes the future of the knee by causing osteoarthritis and axis deviation. The purpose of this study is to evaluate the effect of Trabecular Metal (porous tantalum metal) on stability and strength of fracture repair in the ce...

متن کامل

The Trabecular Metal Monoblock acetabular component in patients with high congenital hip dislocation: a prospective study.

Between November 1997 and December 2000 we performed 27 total hip replacements in 22 patients with high congenital dislocation of the hip using porous tantalum monoblock acetabular components implanted in the true acetabular bed. Clinical and radiological evaluation was performed at regular intervals for a mean of 10.2 years (8.5 to 12). The mean Harris Hip Score improved from 48.3 (15 to 65) p...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

ژورنال

عنوان ژورنال: Knee Surgery, Sports Traumatology, Arthroscopy

سال: 2016

ISSN: 0942-2056,1433-7347

DOI: 10.1007/s00167-016-4271-2