Thyroglobulin Liquid Chromatography–Tandem Mass Spectrometry Has a Low Sensitivity for Detecting Structural Disease in Patients with Antithyroglobulin Antibodies

نویسندگان
چکیده

برای دانلود باید عضویت طلایی داشته باشید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Plasma Free Metanephrines Quantitation with Automated Online Sample Preparation and Liquid ChromatographyTandem Mass Spectrometry

Recently, we reported an LC-MS/MS method for measuring Pmets using ion-pairing solid phase extraction (IP-SPE) and porous graphitic carbon (PGC) column chromatography1, 2. Although the method is fast and analytically sensitive, it can be further improved by automating the offline sample preparation with online sample preparation technology, which is more timeand cost-effective. Thermo Scientifi...

متن کامل

Antithyroglobulin antibodies in patients with differentiated thyroid carcinoma: methods of detection, interference with serum thyroglobulin measurement and clinical significance.

Antithyroglobulin antibodies (TgAb) were measured using a chemiluminescent immunoassay (ICMA) and an agglutination test. TgAb laboratory and clinical interference with Tg measurements were assessed. The course of TgAb concentration and disease status were compared during 3 years after initial treatment. The agglutination test failed to detect all titers < 10 IU/mL (ICMA). Interference from TgAb...

متن کامل

Auto-antibodies in Patients with Inflammatory Bowel Disease Unclassified

Background: Inflammatory bowel disease unclassified (IBDU) is considered to be an aberrant immune response with loss of tolerance to many antigens. Objective: This paper tries to address whether there is any value to test for auto-antibodies in such patients. Methods: 60 patients with inflammatory bowel disease unclassified participated in the study. Auto-antibodies to nuclear antigen, intestin...

متن کامل

Liquid Chromatography Tandem Mass/Mass Spectrometry for the Quantification of Fudosteine in Human Serum without Precolumn Derivatization

A quantitative analysis method for fudosteine in human serum by high-performance liquid chromatography-electrospray ionization tandem mass spectrometry (HPLC-ESI/MS/MS) was established, which shows high sensitivity and selectivity. The mobile phase composition was 75% 20 mM acetic acid and 25% acetonitril, which was pumped at a flow rate of 0.40 mL/min. The overall chromatographic run time was ...

متن کامل

Liquid Chromatography Tandem Mass/Mass Spectrometry for the Quantification of Fudosteine in Human Serum without Precolumn Derivatization

A quantitative analysis method for fudosteine in human serum by high-performance liquid chromatography-electrospray ionization tandem mass spectrometry (HPLC-ESI/MS/MS) was established, which shows high sensitivity and selectivity. The mobile phase composition was 75% 20 mM acetic acid and 25% acetonitril, which was pumped at a flow rate of 0.40 mL/min. The overall chromatographic run time was ...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

ژورنال

عنوان ژورنال: Thyroid

سال: 2017

ISSN: 1050-7256,1557-9077

DOI: 10.1089/thy.2016.0210