THROMBOSIS AFTER BIORESORBABLE VASCULAR SCAFFOLD IMPLANTATION: ANGIOGRAPHIC AND OCT FINDINGS

نویسندگان
چکیده

برای دانلود باید عضویت طلایی داشته باشید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Vascular Healing of a False Lumen After Bioresorbable Scaffold Implantation.

Bioresorbable scaffolds (BRS) are promising devices for the treatment of coronary artery disease by virtue of their resorption properties allowing positive vascular remodeling. This case report illustrates the vascular healing process after Absorb BRS (Abbott Vascular, Santa Clara, CA) implantation in a false lumen during the treatment of a chronic total occlusion. A 62-year-old male with stabl...

متن کامل

Angiographic and Optical Coherence Tomography Insights Into Bioresorbable Scaffold Thrombosis

M etallic drug-eluting stents (DESs) are the current standard for invasive treatment of coronary artery disease. However, metallic DES have been associated with late complications such as neoatherosclerosis and incomplete healing that can lead to failure even at long-term follow-up. Bioresorbable vascular scaffolds (BVSs) are a new treatment for coronary artery disease that could potentially al...

متن کامل

Bioresorbable Coronary Scaffold€Thrombosis

Fro Ka Ca Fra Ma Ab Eg fro ha res Pu Ma BACKGROUND Recent reports suggest an elevated incidence of bioresorbable vascular scaffold (BVS) thrombosis (scaffold thrombosis [ScT]). OBJECTIVES This study investigated occurrence rates, clinical and angiographic characteristics, and possible mechanisms of ScT in all-comer patients undergoing BVS implantation at 2 German and 2 Swiss hospitals. METHODS ...

متن کامل

Management of immediate partial bioresorbable vascular scaffold stent thrombosis.

Bioresorbable vascular scaffold (BVS) stents have been proposed recently as an elegant technique for treatment of coronary artery disease. However, perspective that these "dissolvable" stents will replace conventional metallic stents in broad spectrum of clinical conditions and patient categories in the near future has been moderated by non-negligible incidence of stent thrombosis (ST). Mechani...

متن کامل

Very late thrombosis observed on optical coherence tomography 22 months after the implantation of a polymer-based bioresorbable vascular scaffold.

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . doi:10.1093/eurheartj/ehv046 Online publish-ahead-o...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

ژورنال

عنوان ژورنال: Journal of the American College of Cardiology

سال: 2015

ISSN: 0735-1097

DOI: 10.1016/s0735-1097(15)61735-1