Three-Point Bending Fatigue Test of TiAl6V4 Titanium Alloy at Room Temperature

نویسندگان
چکیده

برای دانلود باید عضویت طلایی داشته باشید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Corrosion Fatigue Studies on a Bulk Glassy Zr-Based Alloy under Three-Point Bending

Corrosion fatigue (CF) tests were carried out on bulk glassy Zr52.5Cu17.9Al10Ni14.6Ti5 (Vitreloy 105) samples under load-controlled three-point bending conditions with a load ratio of R = 0.1 in 0.01 M Na2SO4 + 0.01 M NaCl electrolyte. During cyclic testing, the bar-shaped specimens were polarized in situ at constant potentials and the current was monitored. Three different anodic potentials wi...

متن کامل

Imprinting bulk amorphous alloy at room temperature

We present investigations on the plastic deformation behavior of a brittle bulk amorphous alloy by simple uniaxial compressive loading at room temperature. A patterning is possible by cold-plastic forming of the typically brittle Hf-based bulk amorphous alloy through controlling homogenous flow without the need for thermal energy or shaping at elevated temperatures. The experimental evidence su...

متن کامل

Identification of Low Cycle Fatigue Parameters of High Strength Low-alloy (hsla) Steel at Room Temperature

S. Bulatović, Yugoslav River Shipping, Serbia, Lj. Milović, University of Belgrade, Faculty of Technology and Metallurgy, Serbia, A. Sedmak, University of Belgrade, Faculty of Mechanical Engineering, Serbia, I. Samardžić, University of Osijek, Mechanical Engineering Faculty, Slavonski Brod, Croatia Low cycle fatigue test was performed in ambient atmosphere at room temperature. Cycle loading of ...

متن کامل

Room temperature fracture processes of a near-a titanium alloy following elevated temperature exposure

Near-a titanium alloys are used at higher temperatures than any other class of titanium alloys. As a consequence of thermal exposure, these components may develop locally elevated oxygen concentrations at the exposed surface which can negatively impact ductility and resistance to fatigue crack initiation. In this work, monotonic and fatigue fracture mechanisms of Ti–6Al–2Sn– 4Zr–2Mo–0.1Si sampl...

متن کامل

Heusler alloy showing room temperature half - metallicity at the surface

In this article we investigate the surface spin polarization in a 100 nm Co 2 Cr 0.6 Fe 0.4 Al (CCFA) film grown ex situ epitaxially on MgO(100) with a 10 nm Fe buffer layer by means of spin resolved photoemission. We show that a careful in situ preparation of the sample surface leads to values for the room temperature spin polarization up to 45% at the Fermi level. To our knowledge, this is th...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

ژورنال

عنوان ژورنال: Advances in Materials Science and Engineering

سال: 2019

ISSN: 1687-8434,1687-8442

DOI: 10.1155/2019/2842416