Three-Phase Transformer Inrush Current Reduction Strategy Based on Prefluxing and Controlled Switching

نویسندگان

چکیده

Inrush current with high amplitude is generated when the transformer energized. On one hand, it will have a negative impact on safety of itself, and even cause relay protection to malfunction. other may reduce operation speed there slight fault because restraint criteria. Both aspects affect grid security. Based generation mechanism inrush current, this paper proposes an reduction strategy that combines prefluxing controlled switching technology. By constructing equivalent magnetic circuit model large-capacity three-phase universal core structure, analytical formulas flux at each stage implementing are obtained, then parameters design method proposed. The accuracy theoretical analysis verified through accurate simulation. Compared common strategies, can 0.5 times rated below in any situation where residual unknown “core equalization” effect not obvious, avoiding problem measurement. Finally, case differential protection, influence analyzed from perspective theory simulation, shows improve performance various protections effectively.

برای دانلود باید عضویت طلایی داشته باشید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Transformer inrush current mitigation using controlled switching and magnetic flux shunts

The inrush current is a transient current that results from a sudden change in the exciting voltage across a transformer’s windings. It may cause inadvertent operation of the protective relay system and necessitate strengthening of the transformer’s mechanical structure. Many methods were reported in the literatures for reduction and mitigation of transformer inrush currents. This paper represe...

متن کامل

Mitigation Transformer Inrush Current Using Modified Transient Current Limiter

This study presents a modified transient current limiter (MTCL) for mitigation the inrush current of transformers. The MTCL is based on conventional transient current limiter (TCL), which, its configuration is modified to overcome the TCL drawbacks of operation. The proposed MTCL offers lower power losses and voltage/current THD during normal operation mode. It needs only one limiting reactor i...

متن کامل

Transformer Inrush Current and Related Challenges

Energizing of large power transformers is considered a critical event in the operation of an electric power system. When a transformer is energized by the grid or utility, it takes very high value current known as inrush current, the typical value of this current could be ten times. This inrush causes many problems like mechanical stress on transformer & harmonics injection to generator winding...

متن کامل

Power Transformer Modeling for Inrush Current Calculation

The paper documents a new transformer model in ATPDraw called XFMR. This model handles 3-phase transformers with two or three windings. Autotransformers and all Wye and Delta couplings are supported. The model includes an inverse inductance matrix for the leakage description, optional frequency dependent winding resistance, capacitive coupling, and a topologically correct core model (3and 5-leg...

متن کامل

Reduction of Voltage Stress and Inrush Current of Power Transformers Using Controlled Switching

Random energisation of power transformers often causes significant inrush currents and steep switching voltage wave fronts that are responsible for several adverse effects like huge current forces in the transformer windings, dielectric stress of the transformer winding insulation and temporary overvoltages. Controlled switching taking into account the residual flux is able to eliminate these i...