Three-phase inverter-connected DG-units and voltage unbalance
نویسندگان
چکیده
منابع مشابه
New method of current control for LCL-interfaced grid-connected three phase voltage source inverter
This paper presents an approach for the connection of a photovoltaic generator to the utility grid. A theoretical analysis, modelling, controlling and a simulation of a grid connected photovoltaic system using an output LCL filter are described in detail. In order to reduce the complexity of the system, a linear voltage and current controllers have been developed for a three phase grid connecte...
متن کاملControl of Inverter-Interfaced Distributed Generation Units for Voltage and Current Harmonics Compensation in Grid-Connected Microgrids
In this paper, a new approach is proposed for voltage and current harmonics compensation in grid-connected microgrids (MGs). If sensitive loads are connected to the point of common coupling (PCC), compensation is carried out in order to reduce PCC voltage harmonics. In absence of sensitive loads at PCC, current harmonics compensation scenario is selected in order to avoid excessive injection of...
متن کاملInvestigation of Three-Phase Grid-Connected Inverter for Photovoltaic Application
This paper describes the investigation of the grid-connected three-phase inverter for photovoltaic (PV) application. The inverter control system modeling is carried out in MATLAB/SIMULINK environment. With the aids of the proportional-integral controllers, sinusoidal pulse-width modulation (SPWM) control technique and Park transformation, the inverter control system managed to convert PV power ...
متن کاملDevelopment of 10 kW Three - Phase Grid Connected Inverter
In this paper, modeling, simulation and experimental study of a 10 kW three-phase grid connected inverter are presented. The mathematical model of the system is derived, and characteristic curves of the system are obtained in MATLAB with m-file for various switching frequencies, dc-link voltages and filter inductance values. The curves are used for parameter selection of three-phase grid connec...
متن کاملHarmonic Reduction In Three-Phase Parallel Connected Inverter
This paper presents the design and analysis of a parallel connected inverter configuration of. The configuration consists of parallel connected three-phase dc/ac inverter. Series resistors added to the inverter output to maintain same current in each inverter of the two parallel inverters, and to reduce the circulating current in the parallel inverters to the minimum. High frequency third harmo...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
ژورنال
عنوان ژورنال: Electric Power Systems Research
سال: 2011
ISSN: 0378-7796
DOI: 10.1016/j.epsr.2010.11.024