Three-dimensional Rotational Axis Analysis of Eye Movement as Clinical Applications
نویسندگان
چکیده
منابع مشابه
Use of three-dimensional ultrasonography of the eye and measurement of optical long axis in dog
This study was conducted to determine the use of three-dimensional ultrasonography (3DU) in ocular imaging of the dog and measuring of its optical axis. 12 healthy mixed-breed dogs including 6 males and 6 females were studied. 3DU of the eyes were done using a 5–12 MHz linear trapezoid transducer. 3DU of the eyes were evaluated and the normal optical long axis through a line between the cornea ...
متن کاملuse of three-dimensional ultrasonography of the eye and measurement of optical long axis in dog
this study was conducted to determine the use of three-dimensional ultrasonography (3du) in ocular imaging of the dog and measuring of its optical axis. 12 healthy mixed-breed dogs including 6 males and 6 females were studied. 3du of the eyes were done using a 5–12 mhz linear trapezoid transducer. 3du of the eyes were evaluated and the normal optical long axis through a line between the cornea ...
متن کاملthree-dimensional slope stability analysis with rotational failure mechanism
this paper deals with three-dimensional evaluation of the slopes on the basis of limit analysis. an upper-bound technique of limit analysis is used in this paper to determine either the bearing capacity of a shallow foundation near a slope or the safety factor of the slope. the theorems of limit analysis (upper and lower bound) provide a powerful tool for solving problems in which limit loads n...
متن کاملThree-dimensional rotational myelography.
Three-dimensional (3D) rotational radiography, initially developed to visualize intracranial aneurysms, is applied to the cervical spine after conventional myelography. We call this process 3D rotational myelography. 3D reconstruction and then postprocessing allows imaging in multiple planes. Spinal or nerve root sheath alterations caused by bony or soft tissue can be visualized and differentia...
متن کاملThree-dimensional analysis of orthodontic tooth movement based on XYZ and finite helical axis systems.
The purpose of this study was to demonstrate the advantage of the finite helical axis (FHA) system in the biomechanical analysis of orthodontic tooth movement by comparing it with the rectangular coordinate (XYZ) system. Ten patients (6 females and 4 males, mean age 23 years 7 months) were selected. Maxillary canine retraction using light continuous forces of two different magnitudes (0.5 and 1...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
ژورنال
عنوان ژورنال: Practica Oto-Rhino-Laryngologica
سال: 2007
ISSN: 1884-4545,0032-6313
DOI: 10.5631/jibirin.100.599