Ultrashort echo time imaging using pointwise encoding time reduction with radial acquisition (PETRA).
Sequences with ultrashort echo times enable new applications of MRI, including bone, tendon, ligament, and dental imaging. In this article, a sequence is presented that achieves the shortest possible encoding time for each k-space point, limited by pulse length, hardware switching times, and gradient performance of the scanner. In pointwise encoding time reduction with radial acquisition (PETRA...
متن کاملAnisotropic 3D Radial Sampling for Ultrashort TE Imaging
J. Rahmer, P. Börnert Philips Research Laboratories, Hamburg, Germany Introduction 3D radial free-induction-decay (FID) sampling schemes are used in ultrashort echo-time imaging (UTE), which is a method to visualize short-T2 components in tendons, ligaments, and the like [1-4]. 3D UTE techniques sample a spherical k space volume with isotropic angular resolution, leading to rather long scan dur...
متن کاملDesigning long-T2 suppression pulses for ultrashort echo time imaging.
Ultrashort echo time (UTE) imaging has shown promise as a technique for imaging tissues with T2 values of a few milliseconds or less. These tissues, such as tendons, menisci, and cortical bone, are normally invisible in conventional magnetic resonance imaging techniques but have signal in UTE imaging. They are difficult to visualize because they are often obscured by tissues with longer T2 valu...
متن کاملIn-vivo Visualization of Iron Oxide Enhancement in Focal Pulmonary Inflammatory Lesions Using a Three-Dimensional Radial Gradient-Echo-Based Ultrashort Echo Time Sequence: A Preliminary Study
Objective To preliminarily evaluate technical feasibility of a dual-echo ultrashort echo time (UTE) subtraction MR imaging by using concurrent dephasing and excitation (CODE) sequence for visualization of iron-oxide enhancement in focal inflammatory pulmonary lesions. Materials and Methods A UTE pulmonary MR imaging before and after the injection of clinically usable superparamagnetic iron-ox...
متن کاملOptimized 3D ultrashort echo time pulmonary MRI.
PURPOSE To optimize 3D radial ultrashort echo time MRI for high resolution whole-lung imaging. METHODS 3D radial ultrashort echo time was implemented on a 3T scanner to investigate the effects of: (1) limited field-of-view excitation, (2) variable density readouts, and (3) radial oversampling. Improvements in noise performance and spatial resolution were assessed through simulation and phanto...