Thin-layer chromatography with flame ionization detector for determination of methomyl in serum and urine using a rapid sep pak cartridge extraction.

نویسندگان
چکیده

برای دانلود باید عضویت طلایی داشته باشید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Determination of amniotic fluid phospholipids by thin-layer chromatography, with use of a hydrogen flame ionization detector.

We describe a new specific method for measuring lecithin, sphingomyelin, and phosphatidylglycerol in amniotic fluid by thin-layer chromatography, with use of a hydrogen flame ionization detector. After extraction and acetone precipitation to isolate surface-active lecithin, the phospholipids are separated on a thin rod of refractory and chemically stable material, having an outer coating of a b...

متن کامل

Determination of 2-phenylethanol in Rose Water Using Dispersive Liquid-Liquid Microextraction with Gas Chromatography Flame Ionization Detection

A simple and rapid microextraction procedure based on dispersive liquid-liquid microextraction (DLLME) coupled with gas chromatography-flame ionization detection (GC-FID) was developed for the extraction and analysis of 2-phenylethanol in rose water sample. In the proposed approach, carbon tetrachloride and ethanol were used as extraction and dispersive solvents, respectively. Some important pa...

متن کامل

Residual solvent determination by head space gas chromatography with flame ionization detector in omeprazole API

Residual solvents in pharmaceutical samples are monitored using gas chromatography with head space. Based on good manufacturing practices, measuring residual solvents is mandatory for the release testing of all active pharmaceutical ingredients (API). The analysis of residual organic solvents (methanol, acetone, cyclohexane, dichloromethane, toluene) in Omeprazole, an active pharmaceutical ingr...

متن کامل

Analysis of Heavy Oils by Thin-Layer Chromatography with Flame Ionization Detection†

Several rapid methods for compositional analysis of heavy oils by thin layer chromatography with flame ionization detection (FID-TLC) were investigated. Separating into four fractions, Saturates, Aromatics, Resins, and Asphalten, SARA analysis of heavy oils could be accurately performed by three stage development using n-hexane, toluene, and tetrahydrofuran. Detailed hydrocarbon type analysis o...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

ژورنال

عنوان ژورنال: Eisei kagaku

سال: 1985

ISSN: 0013-273X

DOI: 10.1248/jhs1956.31.141