Thin film metal coated fiber optic hydrophone probe

نویسندگان
چکیده

برای دانلود باید عضویت طلایی داشته باشید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

On fiber optic probe hydrophone measurements in a cavitating liquid.

The measurement of high-pressure signals is often hampered by cavitation activity. The usage of a fiber optic probe hydrophone possesses advantages over other hydrophones, yet when measuring in a cavitating liquid large variations in the signal amplitude are found; in particular when the pressure signal recovers back to positive values. With shadowgraphy the wave propagation and cavity dynamics...

متن کامل

Measurement of high intensity focused ultrasound fields by a fiber optic probe hydrophone.

The acoustic fields of a high intensity focused ultrasound (HIFU) transducer operating either at its fundamental (1.1 MHz) or third harmonic (3.3 MHz) frequency were measured by a fiber optic probe hydrophone (FOPH). At 1.1 MHz when the electric power applied to the transducer was increased from 1.6 to 125 W, the peak positive/negative pressures at the focus were measured to be p(+) = 1.7-23.3 ...

متن کامل

Fiber optic probe hydrophone for the study of acoustic cavitation in water.

We use focused ultrasound bursts to submit a liquid to mechanical tension. When the pressure in the sound wave reaches a sufficiently low value, vapor bubbles are nucleated in the bulk liquid. According to nucleation theory, increasing the ultrasound frequency increases the cavitation threshold by a calculable amount. To check this, we have built a fiber optic probe hydrophone based on one orig...

متن کامل

On Fiber Optic Probe Hydrophone Measurements in a Cavitating Liquid (L)

The measurement of high-pressure signals is often hampered by cavitation activity. The usage of a fiber optic probe hydrophone possesses advantages over other hydrophones, yet when measuring in a cavitating liquid large variations in the signal amplitude are found; in particular when the pressure signal recovers back to positive values. With shadowgraphy the wave propagation and cavity dynamics...

متن کامل

In-plane ultrasonic needle tracking using a fiber-optic hydrophone.

PURPOSE Accurate and efficient guidance of needles to procedural targets is critically important during percutaneous interventional procedures. Ultrasound imaging is widely used for real-time image guidance in a variety of clinical contexts, but with this modality, uncertainties about the location of the needle tip within the image plane lead to significant complications. Whilst several methods...

متن کامل