منابع مشابه
‘Squeezing’ near-field thermal emission for ultra-efficient high-power thermophotovoltaic conversion
We numerically demonstrate near-field planar ThermoPhotoVoltaic systems with very high efficiency and output power, at large vacuum gaps. Example performances include: at 1200 °K emitter temperature, output power density 2 W/cm(2) with ~47% efficiency at 300 nm vacuum gap; at 2100 °K, 24 W/cm(2) with ~57% efficiency at 200 nm gap; and, at 3000 °K, 115 W/cm(2) with ~61% efficiency at 140 nm gap....
متن کاملMie-Metamaterials-Based Thermal Emitter for Near-Field Thermophotovoltaic Systems
In this work, we theoretically analyze the performance characteristics of a near-field thermophotovoltaic system consisting a Mie-metamaterial emitter and GaSb-based photovoltaic cell at separations less than the thermal wavelength. The emitter consists of a tungsten nanoparticle-embedded thin film of SiO 2 deposited on bulk tungsten. Numerical results presented here are obtained using formulae...
متن کاملMeasurement of Direct Photon Emission in K1 ! p1p0g Decay
S. Adler,1 M. Aoki,5,* M. Ardebili,4 M. S. Atiya,1 P. C. Bergbusch,5,7 E. W. Blackmore,5 D. A. Bryman,5,7 I.-H. Chiang,1 M. R. Convery,4 M. V. Diwan,1 J. S. Frank,1 J. S. Haggerty,1 T. Inagaki,2 M. M. Ito,4 S. Kabe,2 S. H. Kettell,1 Y. Kishi,3 P. Kitching,6 M. Kobayashi,2 T. K. Komatsubara,2 A. Konaka,5 Y. Kuno,2 M. Kuriki,2 T. F. Kycia,1, K. K. Li,1 L. S. Littenberg,1 J. A. Macdonald,5 R. A. M...
متن کاملDirect measurement of thermal fluctuation of high-Q pendulum.
We have achieved a direct measurement of the thermal fluctuation of a pendulum in an off-resonant and wide frequency region using a laser interferometric gravitational-wave detector. These measurements have been well identified for over one decade by an agreement with a theoretical prediction, which is derived by a fluctuation-dissipation theorem. Thermal fluctuation was dominated by the contri...
متن کاملGingival Thickness Assessment: Visual versus Direct Measurement
Background and Aim: Several methods have been suggested to measure gingival thick-ness. This study aimed to assess the reliability of visual assessment of facial gingival biotype of maxillary and mandibular teeth with or without using a periodontal probe in comparison with direct measurement. Materials and Methods: Sixty-seven healthy patients (25 women and 42 men) with a total of 100 hopele...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
ژورنال
عنوان ژورنال: Journal of Purdue Undergraduate Research
سال: 2016
ISSN: 2158-4044,2158-4052