Thermometry of intermediate level waste containers using phosphor thermometry and thermal imaging
نویسندگان
چکیده
منابع مشابه
The historical development of thermometry and thermal imaging in medicine.
Human body temperature has been an important part of medicine since very early times. However, until the thermometer was developed in the 16th century measurement was not possible. Some 200 years later, Wunderlich laid the foundation for clinical thermometry, and temperature charts became commonplace throughout the world. More recently thermal imaging has broadened the understanding of body sur...
متن کاملVolumetric thermometry
Background/introduction Many applications of thermal therapy would benefit from temperature distribution measurements with high spatial and temporal resolution that cover a large 3D volume. Although MRI can acquire 3D temperature measurements, it is not possible to obtain fully sampled 3D MRI measurements that cover the insonified field of view with sufficient spatial and temporal resolution fo...
متن کاملCavitation Thermometry Using Molecular and Continuum Sonoluminescence
The use of molecular and continuum emission spectra from multiple bubble (MB) and single bubble (SB) sonoluminescence (SL) is explored as a probe of bubble temperature during cavitational collapse. It is proposed that molecular and continuum SL arise from different chemical pathways, which occur during discrete intervals along the cavitational collapse time line, thus yielding different cavitat...
متن کاملNuclear Thermometry
The concept of a nuclear temperature was introduced some seventy years ago in pioneering works performed by Bethe [1] and Weisskopf [2]. The goal was to describe the formation and the decay of a compound nucleus in reactions induced by light projectiles, mostly neutrons. Later on, the concept of a nuclear temperature was extended to reactions involving highenergy projectiles and heavy ions [3]....
متن کاملProper Noise and Thermometry
Statistical thermodynamic phenomenon of fluctuations (noise) appearance in the controlled substance is under consideration in the proposed work. Their types as well as the relationship among them revealing in the totality of influences on the characteristics of a noise thermometer as a certified metrological mean of measuring the parameters of electric noise have been researched. The background...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
ژورنال
عنوان ژورنال: Measurement
سال: 2019
ISSN: 0263-2241
DOI: 10.1016/j.measurement.2018.09.030