Thermocouple Temperature Measurements in Metalized Explosive Fireballs

نویسندگان

چکیده

The detonation of a metalized explosive generates fireball that has spatially non-uniform distribution particle concentration and gas temperature. transient temperature field must be probed with ruggedized spatially- temporally-resolved diagnostics. use in-situ thermocouples for measurements within multiphase fireballs is demonstrated. Although the thermocouple lags behind local temperature, assessed by modeling sensor assuming first-order response using two analysis methods: (1) when trace reaches extrema, instantaneously equal to (2) reconstructing multiple co-located different lag responses. history at various distances presented charges consisting packed beds particles saturated liquid nitromethane. results reactive (Al, Ti, Zr) are compared non-reactive (Fe), as well homogeneous NM charges. For charges, maximum about 1100 K occurs times on order 100’s milliseconds, less than burning soot in (?1900 K). With Al particles, due jetting combustion, but temperatures up 1800 recorded 0.5 s, (?2700 Inert act heat sink did not exceed 400 K.

برای دانلود باید عضویت طلایی داشته باشید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Problems Encountered in Fluctuating Flame Temperature Measurements by Thermocouple

Some thermocouple experiments were carried out in order to obtain sensitivity of thermocouple readings to fluctuations in flames and to determine if the average thermocouple reading was representative of the local volume temperature for fluctuating flames. The thermocouples considered were an exposed junction thermocouple and a fully sheathed thermocouple with comparable time constants. Either ...

متن کامل

Direct thermocouple measurements of temperature rise and heat conduction in the rabbit retina.

For a given burn, a greater dose was required to raise the temperature to the same level tuhen the spectral distribution of the source included both the visible and the near infrared. Temperature rises compatible with steam production have not been obtained even for very intense burns. In cases of retinal explosion the temperature rose above 40° C, which when added to the body temperature gave ...

متن کامل

Thermocouple Dynamic Errors Correction for Instantaneous Temperature Measurements in Induction Heating

Abstrac t The most commonly used thermometer to measure high temperatures in metallurgy is the thermocouple, but because of its long response time it can be used mainly for measuring time-averaged temperatures. Research on steel wire patenting using inductive heating required instantaneous temperature values. Pyrometers or thermographic cameras could be used, however they are generally expensiv...

متن کامل

An Approach to Thermocouple Measurements That Reduces Uncertainties in High-Temperature Environments

Obtaining accurate temperature measurements with thermocouples in flame environments is challenging due to the effects of radiative heat losses, as these losses are difficult to quantify. Efforts to minimize radiative losses by, for example, suction pyrometry often result in a significant sacrifice in spatial resolution. In this work, a new experimental methodology is presented that both minimi...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

ژورنال

عنوان ژورنال: Propellants, Explosives, Pyrotechnics

سال: 2021

ISSN: ['0721-3115', '1521-4087']

DOI: https://doi.org/10.1002/prep.202000328