Thermo-Hydraulic Performance Evaluation Using W-Discrete Rib in Solar Air Heater
نویسندگان
چکیده
منابع مشابه
A CFD based thermo-hydraulic performance analysis of an artificially roughened solar air heater having equilateral triangular sectioned rib roughness on the absorber plate
In this article, a numerical investigation is conducted to analyze the two-dimensional incompressible Navier–Stokes flows through the artificially roughened solar air heater for relevant Reynolds number ranges from 3800 to 18,000. Twelve different configurations of equilateral triangular sectioned rib (P/e = 7.14–35.71 and e/d = 0.021–0.042) have been used as roughness element. The governing eq...
متن کاملnumerical investigation of thermo-hydraulic characteristics of corrugated air-heater solar collectors
0
متن کاملThermal Performance of a Double-pass Solar Air Heater
This study analyzes the thermal performance of solar thermal energy using double-pass absorber plate in Sanandaj, Iran. To this end, a mathematical model was encoded according to the energy and exergy balance equations and solved by MATLAB software. Given the environmental conditions and radiation intensity of a winter day in Sanandaj, the effects of external parameters such as radiation intens...
متن کاملThermal Hydraulic Performance in a Solar Air Heater Channel with Multi V-Type Perforated Baffles
This article presents heat transfer and fluid flow characteristics in a solar air heater (SAH) channel with multi V-type perforated baffles. The flow passage has an aspect ratio of 10. The relative baffle height, relative pitch, relative baffle hole position, flow attack angle, and baffle open area ratio are 0.6, 8.0, 0.42, 60 ̋, and 12%, respectively. The Reynolds numbers considered in the stud...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
ژورنال
عنوان ژورنال: Indian Journal of Science and Technology
سال: 2016
ISSN: 0974-5645,0974-6846
DOI: 10.17485/ijst/2016/v9i17/89056