Thermal Performance of Heat Exchanger Using Zeolite/vapour Adsorption
نویسندگان
چکیده
About 60% of the energy input in chemical industry is discarded from plant. Energy saving can be achieved entire plant by recovering these waste heats and reusing them as power heat sources An adsorption pump has been developed for purpose regeneration such unused energy. In this study, saturated humid air was supplied to a device packed with 13X zeolite particles 4 mm diameter. The time variation temperature apparatus measured experimentally. Then, maximum estimated relationship between balance equilibrium. trend calculated consistent experiment. Further, it found result equation that sensible are mainly distributed zeolite. future, important make effective use order extract more thermal device, necessary improve transfer bed medium. A double pipe exchanger having on annular side proposed an apparatus. Flow direction changed two different ways. one supplying radial flowly another parallel flow. influence flow medium studied numerical simulation.
منابع مشابه
Analysis of Gasketed-plate Heat Exchanger Performance Using Nanofluid
A heat exchanger using nanofluid needs to operate at optimum mass concentration level to get the maximum heat transfer performance. A numerical analysis is performed on the heat transfer and pressure drop of water-based γ-Al2O3 nanofluid gasketed-plate heat exchanger to specify its optimum conditions. Cold water will be heated by γ-Al2O3/water nanofluid. The results showed that optimal volume c...
متن کاملIntermediate Heat Exchanger Dynamic Thermal Response
This report presents UCB progress in developing a comprehensive thermal and fluid dynamics model for the NGNP intermediate heat exchanger (IHX) and other compact heat exchangers. For nuclear hydrogen applications, an IHX is required to transfer heat from high temperature and high-pressure primary helium coolant to a hydrogen production process. An intermediate heat transfer loop is used for the...
متن کاملEffect of baffle oientation on shell tube heat exchanger performance
In this paper, fluid flow and heat transfer in the laboratory (small size) shell tube heat exchanger are analysed by computational fluid dynamic software. In this type of shell tube heat exchanger baffles with different angles of rotation: 00 (horizontal segmental baffle), 150 (from horizontal), 300, 450, 600, 750, 900 (vertical segmental baffle) is used. Effect of baffle orientation on shell t...
متن کاملExperimental Investigation on Hydrodynamic and Thermal Performance of a Gas-Liquid Thermosyphon Heat Exchanger in a Pilot Plant
Waste heat recovery is very important, because not only it reduces the expenditure of heat generation, but also it is of high priority in environmental consideration, such as reduction in greenhouse gases. One of the devices is used in waste heat recovery is heat pipe heat exchanger.Anexperimental research has been carried out to investigate the hydrodynamic and thermal performance of a gas...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
ژورنال
عنوان ژورنال: MATEC web of conferences
سال: 2021
ISSN: ['2261-236X', '2274-7214']
DOI: https://doi.org/10.1051/matecconf/202133303006