THERMAL PERFORMANCE EVALUATION OF ROOM AIR CONDITIONERS EVAPORATORS

نویسندگان
چکیده

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

A Compact Horizontal Scroll Type Compressor for Room Air Conditioners

This paper presents the construcrion, newly developed design technologies and performance characteristics of a compact horizontal scroll-type compressor for room air conditione~:s. The authors were able lo develop a compacl variable speed horizontal scroll-type compressor with a cooling capacity of I. 8 kW, which necessitated the development of new mechanisms, namely, an alCial compliance mecha...

متن کامل

EER Improvement for Room Air-Conditioners in Saudi Arabia

This paper demonstrates the possibility of achieving a higher Energy Efficiency Ratio (EER) for Room Air Conditioners (RACs) that complies with the Saudi energy efficiency standards and satisfies the energy conservation requirements for the Saudi Building Code (SBC). This study considers several design options for improving the performance and efficiency of the RAC in comparison with a baseline...

متن کامل

Performance of Alternative Refrigerants in Heat Pumps and Air Conditioners

In this paper the results of both modeling and testing a representative 3-ton air-to-air heat pump running with the baseline refrigerant (HCFC-22) and zero ODP alternative refrigerants will be presented. Alternative refrigerant simulation runs are made with two pure fluids (HFC-134a and HFC-152a) and an azeotropicmixture (60/40wt%) ofHFC-32 and HFC125 (Allied-Signal Inc. U.S. Patent 4,978,467)....

متن کامل

Effects of Condensate and Initial Formation of Thin Frost Layer on Evaporator Coil Performance of Room Air-Conditioners

This study investigated experimentally and theoretically, how condensate and initial formation of a thin frost layer on the surface of the evaporator affects the evaporator performance of room air-conditioners compared to dry coil conditions. The theoretically obtained results were validated with the measured values in both wet and initial frost formation conditions and a good correlation was f...

متن کامل

Performance Evaluation Of Peripheral-Finned Tube Evaporators Under Frosting Conditions

The peripheral finned-tube (PFT) is a novel air-side geometry for compact heat exchangers. Previous studies (Pussoli et al., 2012) evaluated the thermal-hydraulic performance of the PFT geometry under dry conditions (i.e., no frost or condensate formation on the air side). The present study focuses on quantifying the thermal-hydraulic performance of the PFT geometry under frosting conditions. A...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

ژورنال

عنوان ژورنال: Revista de Engenharia Térmica

سال: 2005

ISSN: 1676-1790

DOI: 10.5380/reterm.v4i1.3550