Thermal Loads Map and Overall Energy Analysis Depending on Low-Effort Parameters Change: A Commercial Building Case Study
نویسندگان
چکیده
Starting from the second half of 2022, energy market, in particular, European natural gas supply, passed through an eventful period. The sanctions imposed on Russia because Ukrainian war rearranged steadiness suppliers to continent, and major concerns arose regarding reduction primary consumption, particularly for heating cooling purposes. This study proposes a method mapping loads building as function effortlessly changeable boundary conditions (i.e., heating/cooling temperature set-point, infiltration rate work shift); simulation thermal well final estimation was carried out with DesignBuilder, Energyplus-based software, dynamic calculation approach. Thermal load maps provide immediate picture achievable savings represents effective tool monitoring; addition, can support managers policymakers rapidly complying unexpected scenarios. has been applied non-residential results showed that up 40% could be reached, ensuring adequate indoor comfort. Finally, analysis benefit switching fossil fuel boilers electric heat pumps space due minimum saving 70%.
منابع مشابه
A Multi-Scenario Zero-Energy Building Techno-Economic Case Study Analysis for a Renovation of a Residential Building
According to the previous pieces of research, the building sector consumes about 40 % of total yield energy and produce one-third of GHG pollution emission. This point shows the significant potential in two aspects of energy optimization and pollution reduction in this field. The purpose of this research as a case study is to construct a residential building and develop the paths for reaching a...
متن کاملThe Impact of Insulation and HVAC Degradation on Overall Building Energy Performance: A Case Study
Through monitoring of buildings, it can be proven that the performance of envelope elements and energy supply systems deteriorates with time. The results of this degradation are higher energy consumption and life cycle costs than projected in the building design phase. This paper considers the impacts of this deterioration on the whole building energy performance with the goal of improving the ...
متن کاملtechnical and legal parameters for determination of river boundary,( case study haraz river)
چکیده با توسعه شهر نشینی و دخل و تصرف غیر مجاز در حریم رودخانه ها خسارات زیادی به رودخانه و محیط زیست اطراف آن وارده می شود. در حال حاضر بر اساس آئین نامه اصلاح شده بستر و حریم رودخانه ها، حریم کمی رودخانه که بلافاصله پس از بستر قرار می گیرد از 1 تا20 متر از منتهی الیه طرفین بستر رودخانه تعیین، که مقدار دقیق آن در هر بازه از رودخانه مشخص نیست. در کشورهای دیگر روشهای متفاوتی من جمله: درصد ریسک...
15 صفحه اولa study on construction of iranian life tables: the case study of modified brass logit system
چکیده ندارد.
15 صفحه اولMethods for detailed energy data collection of miscellaneous and electronic loads in a commercial office building
Miscellaneous and electronic loads (MELs) consume about 20% of the primary energy used in U.S. buildings, and this share is projected to increase for the foreseeable future. Our understanding, however, of which devices are most responsible for this energy use is still rudimentary due to the difficulty and expense of performing detailed studies on MELs and their energy use. In order to better un...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
ژورنال
عنوان ژورنال: Sustainability
سال: 2023
ISSN: ['2071-1050']
DOI: https://doi.org/10.3390/su15086899