Theoretical study on separate sensible and latent cooling air-conditioning system
نویسندگان
چکیده
منابع مشابه
Development of a Novel Structure Rotary Compressor for Separate Sensible and Latent Cooling Air-Conditioning System
The energy efficiency of separate sensible and latent cooling (SSLC) airconditioning system is higher than traditional one, since SSLC system uses separate cycles which can raise the evaporating temperature of sensible cycle. Separate cycles often include two separate compressors, which makes the initial investment of SSLC cycle too expensive to use in room air conditioning. A novel structure r...
متن کاملStudy On Energy Efficient Operation of Air-conditioning Cooling Water System
The control logic of frequency adjustment for pump and cooling tower fan has been presented in this paper, based on the operation mode of a chiller with one pump and one cooling tower. Optimum outlet water temperature control of cooing tower has been put forward through analysis and comparison among factors influencing it based on measured data. A mathematical model of energy consumption has be...
متن کاملDesign of a Radiant Panel Cooling System for Summer Air Conditioning System
The main objective of this investigation was to design and investigate a radiant panel cooling system on small scale building type (office) under the central Sudan climatic conditions so as to explore the benefits of radiant cooling systems over conventional air conditioning systems (Variable air volume systems). Transient heat conduction of building (finite difference method) was used to evalu...
متن کاملFully Fresh Air Air-conditioning System Equipped with Double Heat Pipe Based Heat Recovery Technology
The using of double heat pipe based heat exchanger (HPHX) in a conventional fully fresh air air-conditioning (AC) system was examined in the present study. The fabricated HPHXs were tested under the actual conditions and the measured data were used to study the performance of the existing AC system (System A) and AC system equipped with the double HPHX (System B) for a yearly operation through ...
متن کاملExergy and Thermoeconomic Analysis for an Underground Train Station Air-Conditioning Cooling System
The necessity of air-conditioning causes the enormous energy use of underground train stations. Exergy and thermoeconomic analysis is applied to the annual operation of the air-conditioning system of a large underground train station in Taiwan. The current installation and the monitored data are taken to be the base case, which is then compared to three different optimized designs. The total re...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
ژورنال
عنوان ژورنال: International Journal of Refrigeration
سال: 2010
ISSN: 0140-7007
DOI: 10.1016/j.ijrefrig.2009.11.011