Theoretical Global Warming Impact Evaluation of Medium and High Temperature Heat Pumps Using Low GWP Refrigerants
نویسندگان
چکیده
This study provides a global warming impact analysis of environmentally friendly refrigerants used as replacements for R134a and R245fa. R290, R1234yf, R1234ze(E), R513A R450A are considered to replace in medium temperature applications. For R245fa, there five alternative refrigerants, R1224yd(Z), R600, R1336mzz(Z), R1233zd(E) R1234ze(Z), which selected high-temperature The is done considering the emission factors Brazil, Sweden, Canada Poland. In Sweden total equivalent per heating capacity higher than its application, although exhibits coefficient performance alternatives. applications, R1336mzz(Z) has lowest due other tested refrigerants. highest belongs R245fa all countries except Poland, where R600 value lower relatively factor Poland compared countries. These results revealed that addition potential, associated with sources electricity generation crucial on indirect emissions.
منابع مشابه
AHRI Low Global Warming Potential Alternative Refrigerants Evaluation Program (Low-GWP AREP) â•fi Summary of Phase I Testing Results
The Air-Conditioning, Heating, and Refrigeration Institute (AHRI) recently completed the first phase of its low global warming potential alternative refrigerants evaluation program (Low-GWP AREP). This industry-wide cooperative research program identified and evaluated promising alternative refrigerants’ performance over the past two years. Thirty-eight low-GWP refrigerants were tested during t...
متن کاملAHRI Low Global Warming Potential Alternative Refrigerants Evaluation Program (Low-GWP AREP) – Summary of Phase II Testing Results
The Air-Conditioning, Heating, and Refrigeration Institute (AHRI) recently completed the second phase of its Low Global Warming Potential Alternative Refrigerants Evaluation Program (Low-GWP AREP). This industry-wide cooperative research program identified and evaluated promising alternative refrigerants over the past five years. Seventeen low-GWP refrigerants were tested during the second phas...
متن کاملAn Evaluation of the Environmental Impact of Different Commercial Supermarket Refrigeration Systems Using Low Global Warming Potential Refrigerants
Commercial refrigeration systems consumed 1.21 Quads of primary energy in 2010 and are known to be a major source for refrigerant charge leakage into the environment. Thus, it is important to study the environmental impact of commercial supermarket refrigeration systems and improve their design to minimize any adverse impacts. The system's Life Cycle Climate Performance (LCCP) was presented as ...
متن کاملSome Practical Results Obtained with Non-Aezotropic Mixtures of Refrigerants in High Temperature Heat Pumps
متن کامل
Limited options for low-global-warming-potential refrigerants
Hydrofluorocarbons, currently used as refrigerants in air-conditioning systems, are potent greenhouse gases, and their contribution to climate change is projected to increase. Future use of the hydrofluorocarbons will be phased down and, thus replacement fluids must be found. Here we show that only a few pure fluids possess the combination of chemical, environmental, thermodynamic, and safety p...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
ژورنال
عنوان ژورنال: Applied sciences
سال: 2021
ISSN: ['2076-3417']
DOI: https://doi.org/10.3390/app11157123