The ZEPLIN II dark matter detector: Data acquisition system and data reduction
نویسندگان
چکیده
منابع مشابه
The Zeplin Ii Dark Matter Detector: Data Acquisition System and Data Reduction the Zeplin Ii Dark Matter Detector: Data Acquisition System and Data Reduction
ZEPLIN II is a two-phase (liquid/gas) xenon dark matter detector searching for WIMP-nucleon interactions. In this paper we describe the data acquisition system used to record the data from ZEPLIN II and the reduction procedures which parameterise the data for subsequent analysis.
متن کاملThe ZEPLIN II dark matter detector : data acquisition system and data reduction
ZEPLIN II is a two-phase (liquid/gas) xenon dark matter detector searching for WIMP-nucleon interactions. In this paper we describe the data acquisition system used to record the data from ZEPLIN II and the reduction procedures which parameterise the data for subsequent analysis.
متن کاملThe Zeplin-iii Dark Matter Detector: Instrument Design, Manufacture and Commissioning
We present details of the technical design and manufacture of the ZEPLIN-III dark matter experiment. ZEPLIN-III is a two-phase xenon detector which measures both the scintillation light and the ionisation charge generated in the liquid by interacting particles and radiation. The instrument design is driven by both the physics requirements and by the technology requirements surrounding the use o...
متن کاملThe ZEPLIN-III dark matter detector: performance study using an end-to-end simulation tool
We present results from a GEANT4-based Monte Carlo tool for end-to-end simulations of the ZEPLIN-III dark matter experiment. ZEPLIN-III is a two-phase detector which measures both the scintillation light and the ionisation charge generated in liquid xenon by interacting particles and radiation. The software models the instrument response to radioactive backgrounds and calibration sources, inclu...
متن کاملFirst limits on WIMP nuclear recoil signals in ZEPLIN-II: A two-phase xenon detector for dark matter detection
Results are presented from the first underground data run of ZEPLIN-II, a 31 kg two-phase xenon detector developed to observe nuclear recoils from hypothetical weakly interacting massive dark matter particles. Discrimination between nuclear recoils and background electron recoils is afforded by recording both the scintillation and ionisation signals generated within the liquid xenon, with the r...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
ژورنال
عنوان ژورنال: Nuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment
سال: 2008
ISSN: 0168-9002
DOI: 10.1016/j.nima.2007.11.005