The UHV system of the 10 MeV RF electron linac
نویسندگان
چکیده
منابع مشابه
Benchmarking of Siemens Linac in Electron Modes: 8-14 MeV Electron Beams
Introduction: Radiation therapy using electron beams is a promising method due to its physical dose distribution. Monte Carlo (MC) code is the best and most accurate technique for forespeaking the distribution of dose in radiation treatment of patients.Materials and Methods: We report an MC simulation of a linac head and depth dose on central axis, along with profile calculations. The purpose o...
متن کاملThe SNS Linac RF Control System
The SNS linac RF control system (RFCS) is currently in development. A system is being installed in a superconducting test stand at Jefferson Laboratory presently. Two systems will soon be installed at Oak Ridge National Laboratory (ORNL) and more are due to be installed early next year. The RF control system provides field control for the entire SNS linac, including an RFQ and 6 DTL cavities at...
متن کاملDigital Rf Control System for 400-mev Proton Linac of Jaeri/kek Joint Project
At the proton linac of the JAERI and KEK Joint Project, an accelerating electric field stability of +-1% in amplitude and +-1 degree in phase is required for the RF system. In order to accomplish these requirements, a digital feedback system is adopted for flexibility of the feedback (FB) and feed forward (FF) algorism implimentation. FPGAs are used for the real-time FB system. A DSP board is a...
متن کاملThe Rf Source of the 60-mev Linac for the Kek/jaeri Joint Project
The construction of the 60-MeV proton linac has started as a low-energy front of the KEK/JAERI Joint Project for a high-intensity proton accelerator facility at KEK. The accelerating frequency is 324 MHz. Five UHF klystrons are used as an rf source; their ratings have a maximum power of 3 MW, a beam pulse width of a 700 μsec (an rf pulse width is 650 μsec) and a repetition rate of 50 pps. We ha...
متن کاملOperation of the Linac and the Linac Rf System for the Ion-beam Therapy Center Heidelberg
The Heidelberg Ion Therapy Center HIT is in clinical operation since 2009. It is the first dedicated European particle accelerator for medical treatment. Its central location on the campus of the Heidelberg University Hospital fits perfectly in the clinical everyday life. The accelerator complex consists of a linear accelerator and a synchrotron and is designed for protons and carbon ions, but ...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
ژورنال
عنوان ژورنال: Journal of Physics: Conference Series
سال: 2008
ISSN: 1742-6596
DOI: 10.1088/1742-6596/114/1/012026