The third generation Carpentier-Edwards bioprosthesis: Early results

نویسندگان
چکیده

برای دانلود باید عضویت طلایی داشته باشید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Cuff leakage, not paravalvular leakage, in the Carpentier Edwards PERIMOUNT Magna Ease aortic bioprosthesis.

Though the Carpentier Edwards PERIMOUNT Magna Ease valve is a bioprosthesis with documented excellent haemodynamics and easy implantability, this valve has a gap between the cobalt-chromium-nickel alloy stent and silicone sewing ring. This gap, which is widest just below each of the three commissural struts, lacks silicone and leaves the two-layer polytetrafluoroethylene fabric unsupported and ...

متن کامل

The Carpentier-Edwards Perimount Magna mitral valve bioprosthesis: intermediate-term efficacy and durability

BACKGROUND The Carpentier-Edwards Perimount Magna mitral valve bioprosthesis (Edwards Lifesciences, Irvine, CA) is a low-profile version of the earlier Perimount valve that uses the ThermaFix process for enhanced calcium removal. The Magna valve has been in use since 2008, yet no publication, until now, has verified its intermediate-term safety and efficacy. METHODS From 2008 through 2011 (ou...

متن کامل

Early Doppler-echocardiography evaluation of Carpentier-Edwards Standard and Carpentier-Edwards Magna aortic prosthetic valve: comparison of hemodynamic performance

OBJECTIVES This study was designed to describe Doppler-echocardiography values of Carpentier-Edwards Perimount Standard (CEPS) and Carpentier-Edwards Perimount Magna (CEPM) aortic prosthetic valves, evaluated by a single, experienced echo-laboratory, early in the postoperative phase. METHODS Three-hundred-seventy-seven consecutive patients, who had had a CEPS or a CEPM implanted in our Hospit...

متن کامل

Hancock, and Carpentier-Edwards heart valve prostheses

From 1975 to 1979, 540 patients undergoing valve replacement were entered into a randomized trial and received either a Bjdrk-Shiley (273 patients) or a porcine heterograft prosthesis (initially a Hancock valve [107 patients] and later a Carpentier-Edwards prosthesis [ 160 patients]). Two hundred and sixty-two patients required mitral valve replacement, 210 required aortic valve replacement, 60...

متن کامل

Comparison of the effects of aortic valve replacement using 19-mm Carpentier-Edwards Perimount bioprosthesis and 19-mm Medtronic Mosaic bioprosthesis.

OBJECTIVE Short (< or =3 months)- and middle (> or =4 months)-term results of aortic valve replacement (AVR) using 19-mm Carpentier-Edwards Perimount (CEP) bioprosthetic valves and 19-mm Medtronic Mosaic (MM) bioprosthetic valves in patients with small aortic annulus were compared. PATIENTS AND METHODS At our facility, AVR was performed using bioprostheses in 110 patients from April 1999 to M...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

ژورنال

عنوان ژورنال: Journal of the American College of Cardiology

سال: 1985

ISSN: 0735-1097

DOI: 10.1016/s0735-1097(85)80323-5