The Straightness Measurement Based on Improved Displacement Method.

نویسندگان
چکیده

برای دانلود باید عضویت طلایی داشته باشید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

A straightness error measurement method matched new generation GPS

The axis of the non-diffracting beam produced by an axicon is very stable and can be adopted as the datum line to measure the spatial straightness error in continuous working distance, which may be short, medium or long. Though combining the non-diffracting beam datum-line with LVDT displace detector, a new straightness error measurement method is developed. Because the Non-diffracting beam dat...

متن کامل

A novel method to enhance the sensitivity for two-degrees-of-freedom straightness measurement

A low cost and high precision system which can measure two-degrees-of-freedom straightness simultaneously is proposed based on a laser collimator. In the system, a miniature fiber coupled diode laser generates a collimating beam. The sensitivity of the straightness error measurement is magnified by a factor of 4 compared with the lateral movement of the retro-reflector itself after the multi-re...

متن کامل

A Displacement Method Based on Field Analysis

As an important operator in polygon cluster generalization, the displacement has two contributions. One is to resolve the proximity conflicts to guarantee the legibility constraint. Another is to act as the prior operator of other generalization operator, such as aggregation. This paper presents a field based method to deal with the displacement of polygon cluster in both aspects above. On the ...

متن کامل

Optoacoustic imaging based on the interferometric measurement of surface displacement.

We present images of tissue phantoms and chicken chorio-allantoic membrane vasculature using a novel optoacoustic tomography technique based on the time-resolved interferometric measurement of laser-induced thermoelastic expansion. Our imaging system is based on a modified Mach-Zehnder interferometer that provides surface displacement measurements with a temporal resolution of 4 ns and a displa...

متن کامل

Modification of Displacement Coefficient Method in Estimation of Target Displacement for Regular Concrete Bridges Based on ASCE 41-06 Standard

Displacement Coefficient Method (DCM) stipulated in the ASCE 41-06 standard is becoming the preferred method for seismic rehabilitation of buildings in many high-seismic-hazard countries. Applications of the method for non-building constructions such as bridges are beyond the scope of this standard. Thus its application to this kind of structure should be approached with care. Target displaceme...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

ژورنال

عنوان ژورنال: TRANSACTIONS OF THE JAPAN SOCIETY OF MECHANICAL ENGINEERS Series C

سال: 2000

ISSN: 0387-5024,1884-8354

DOI: 10.1299/kikaic.66.2010