The Spin-Echo System Reconsidered

نویسندگان

چکیده

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Fast Spin Echo Imaging

In conventional spin echo (SE) imaging, the longitudinal magnetization (that is generated by the presence of the main magnetic field, B0) is tipped into the transverse plane using a radiofrequency (RF) pulse that tips the magnetization 90 degrees. Once in the transverse plane, the magnetization rotates, or precesses, around the axis of the main magnetic field. As the transverse magnetization pr...

متن کامل

Simultaneous spin-echo refocusing.

A new approach to spin-echo imaging is presented in which the 180 degrees RF pulse refocuses two or more spin-echoes at different positions in the readout period. When simultaneous echo refocusing (SER) is implemented using multiple 180 degrees pulses, an undesirable mixing of stimulated echoes and primary echoes from different slices can occur. A novel periodic gradient spoiler scheme eliminat...

متن کامل

Fast Spin- Echo

Imaging with T2-weighting is prescribed in nearly every diagnostic imaging protocol, owing to the fact that in many pathologic states, diseased tissue may be distinguished from normal tissue through apparent differences in T2. Conventional T2-weighted imaging carries with it a heavy time cost, however, as a relatively long time must be allowed between acquisitions in order to allow T1 recovery ...

متن کامل

Assessment of the Characteristics of MRI Coils in Terms of RF Non-Homogeneity Using Routine Spin Echo Sequences

Introduction: One of the major causes of image non-uniformity in MRI is due to the existence of  non-homogeneity in RF receive and transmit. This can be the most effective source of error in  quantitative  studies  in  MRI  imaging.  Part  of  this  non-homogeneity  demonstrates  the  characteristics of RF coil and part of it is due to the interaction of RF field with the material being  imaged...

متن کامل

comparison of maximum signal intensity of magnevist contrast agent in modified t1 weighted spin echo, t1 weighted fast spin echo and t1 weighted gradient echo sequences

background:  nowadays mri examinations have been widely used in clinical applications for many diagnoses. the use of contrast agent in mri improves lesion detection and characterization and causes more accurate diagnosis.  objectives: the aim of this study was comparing to optimal dose of magnevist contrast agent in modified t1w se (spin echo), t1w fse (fast spin echo) and t1w gre (gradient ech...

متن کامل