The small-angle performance of a dual-readout fiber calorimeter

نویسندگان
چکیده

برای دانلود باید عضویت طلایی داشته باشید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Glass Bead Calorimeter and Fiber Optic Readout

Large volume calorimeters are traditionally based on construction from high-density material or a “sandwich” construction of alternating layers of active and passive material. Dense scintillating material, made from materials such as BGO or lead-glass, is too costly to be used on a very large scale. In sandwich technology, energy resolution is often reduced due to a large fraction of the signal...

متن کامل

The CMS Electromagnetic Calorimeter Readout

CMS is a general-purpose detector designed for use in the large hadron collider (LHC) at CERN. The electromagnetic calorimeter will play an important role in electron and photon energy measurements. The benchmark process to evaluate and optimize its performance is H −→ γγ in the intermediate mass range (90 < mH < 150 GeV). For this purpose, each element of the readout chain has to be optimized....

متن کامل

Calice Electromagnetic Calorimeter Readout Status

The CALICE Electromagnetic CALorimeter (ECAL) will be a silicon-tungsten sampling calorimeter [1] with 30 layers of silicon wafers, each containing an 18×18 array of diode pads, giving 9720 channels to be read out. The signal from each pad is amplified by a Very Front End (VFE) ASIC [2] which multiplexes the signals from 18 pads onto one output line. The silicon wafers and VFE chips are mounted...

متن کامل

The ZEUS Forward Plug Calorimeter with Lead-Scintillator Plates and WLS Fiber Readout

A Forward Plug Calorimeter (FPC) for the ZEUS detector at HERA has been built as a shashlik lead-scintillator calorimeter with wave length shifter fiber readout. Before installation it was tested and calibrated using the X5 test beam facility of the SPS accelerator at CERN. Electron, muon and pion beams in the momentum range of 10 to 100 GeV/c were used. Results of these measurements are presen...

متن کامل

Description of a Dual Calorimeter

A dual calorimeter is described which can be used to study electrolytic processes. Experience with this instrument has revealed several deficiencies inherent in the isoperibolic calorimeter design that apply to all calorimeters of this type when used to study the cold fusion effect. I. BACKGROUND A calorimeter has been designed to measure heat energy produced in a Pons-Fleischmann type electrol...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

ژورنال

عنوان ژورنال: Nuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment

سال: 2016

ISSN: 0168-9002

DOI: 10.1016/j.nima.2015.11.005