The Shear Behavior of Insulated Precast Concrete Sandwich Panels Reinforced with BFRP
نویسندگان
چکیده
Typical insulated precast concrete sandwich panel (PCSP) systems are composed of two wythes separated by a layer insulation. The structural behavior PCSP heavily depends on elements between known as connectors, which ensure they work whole. Double shear tests were carried out 58 specimens reinforced with basalt fiber-reinforced polymer (BFRP) connectors; failure modes, load displacement curves and bearing capacity BFRP connectors obtained. Effects diameter, insulation thickness, installation angle, layout spacing combined action analyzed. results show that the span ratio connector was suggested to be less than 15, angle should set 60° or 75° for suitable stiffness an abundant safety margin. decreases slightly increase in connectors’ while overall impact is small. force plane spatial combination can calculated according one single connector. Moreover, model proposed this paper provides favorable design option using connectors.
منابع مشابه
Composite Behavior of a Novel Insulated Concrete Sandwich Wall Panel Reinforced with GFRP Shear Grids: Effects of Insulation Types
A full-scale experimental program was used in this study to investigate the structural behavior of novel insulated concrete sandwich wall panels (SWPs) reinforced with grid-type glass-fiber-reinforced polymer (GFRP) shear connectors. Two kinds of insulation-expanded polystyrene (EPS) and extruded polystyrene (XPS) with 100 mm thickness were incased between the two concrete wythes to meet the in...
متن کاملConnections for Precast Concrete Load-bearing Shear Wall Panels
Precast load-bearing shear wall panels are used extensively for high-rise construction because of the ease and speed of assembly, and the high quality of the precast panels. The connections between panels are extremely important since they affect both the speed of erection '~md the overall integrity of the structure. This paper presents the results of a four-year research program conducted to i...
متن کاملComposite Behavior of Insulated Concrete Sandwich Wall Panels Subjected to Wind Pressure and Suction
A full-scale experimental test was conducted to analyze the composite behavior of insulated concrete sandwich wall panels (ICSWPs) subjected to wind pressure and suction. The experimental program was composed of three groups of ICSWP specimens, each with a different type of insulation and number of glass-fiber-reinforced polymer (GFRP) shear grids. The degree of composite action of each specime...
متن کاملDesigning a prefabricated sandwich composite roofing system Made up of resisting facings and light-weight concrete core with truss-shaped connectors
In this paper, a new roofing system is introduced, which is constructued using the precast composite sandwich panels. This roofing sandwich panels system consists of three kinds of precast concrete sandwich panels including capital panels, beam or between columns panels, and slab or middle panels. The panels are composed of three layers; A high strength reinforced concrete top layer. A thick la...
متن کاملHysteretic Behavior of Conventionally Reinforced Concrete Coupling Beams in Reinforced Concrete Coupled Shear Wall
This paper presents the experimental results of four full-scale coupling beams in which only horizontal reinforcements are placed, without diagonal reinforcements, with the aim to develop reinforcement details for coupling beams used in connecting side walls in a wall-slab structural system. Each coupling beam specimen was designed according to the deep-beam design procedure that does not use d...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
ژورنال
عنوان ژورنال: Buildings
سال: 2022
ISSN: ['2075-5309']
DOI: https://doi.org/10.3390/buildings12091326