The Sensitivity of Leersia hexandra Sw. to Gamma-Ray Irradiation
نویسندگان
چکیده
Gamma-ray irradiation as a physical mutagen has high penetrating power. Therefore, it is most often used to increase genetic variability or produce new mutant plants. This research was conducted obtain the lethal dose of gamma-rays in Leersia hexandra The plant part single node stolon which had length 10 cm with middle stolon. doses given were 0, 25, 50, 75, 100 Gy. Stolons inserted into plastic clips and irradiated using Cobalt-60 gamma source at Center for Irradiation Radioisotope Applications (PAIR), National Nuclear Energy Agency (BATAN) Jakarta. Gamma-irradiation significant effect on inhibiting shoot growth. growth best number plants highest shoots obtained 25 Gy decreased increasing dose. (LD 50 ) determined eight days after CurveExpert 1.4 software. that can sprout regenerate followed linear equation y = 1.02 - 7.5x LD 68.85 20 29.36 Keywords: irradiation, variation, , dose, plant.
منابع مشابه
Water Absorption of Chitosan, Collagen and Chitosan/Collagen Blend Membranes Exposed to Gamma-ray Irradiation
TThis study investigated the water absorption of chitosan, collagen, and chitosan/collagen blend membranes exposed to gamma-ray irradiation. These membranes were produced via the solvent evaporation method. All membranes then underwent irradiation at 15 or 25 kGy gamma-ray doses, while membranes without irradiation were used as controls. After immersing the membranes in distilled water for up t...
متن کاملGenetic Differentiation Caused by Chromium Treatment in Leersia hexandra Swartz Revealed by RAPD Analysis
Randomly amplified polymorphic DNA (RAPD) technique was applied to assess the genetic variations and phylogenetic relationships in genetic differentiation within 4 Chromium-treatment Leersia hexandra. The fresh leaves of Leersia hexandra cultivated on the condition of chrome pollution and exogenous organic acids were used as experimental material. The genomic DNA of Leersia hexandra was extract...
متن کاملSimulation of gamma-ray gamma rays by composite shields compared to the lead protection using the MCNPX code
In this study, cobalt 60 with a mean energy of (1.25 Mev) was used as a photonic source to investigate the effect of decreasing gamma-ray intensity by materials and polymer composite using MCNPX code. First, we investigated the effect of thickness and density on the reduction of gamma ray intensity, and then the comparison between the lead protector, tungsten and polymer composite in several th...
متن کاملGamma ray Sensitivity of Superheated Liquid
INTRODUCTION The superheated drop detector (SDD) is composed of droplets of a sensitive liquid with low-boiling point and a medium supporting the droplets dispersed throughout the medium. The SDD has been mainly used for neutron dosimetry and recently also for γ -rays. However the conditions of bubble formation have been discussed for neutrons but there have been a little works for gamma-rays. ...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
ژورنال
عنوان ژورنال: The journal of experimental life science
سال: 2021
ISSN: ['2338-1655', '2087-2852']
DOI: https://doi.org/10.21776/ub.jels.2021.011.01.02