The Resuming Insulation Discharge Failure and Conductor Overheating Failure Judgment Method of SF6 Electrical Equipment
نویسندگان
چکیده
منابع مشابه
Optimal Modeling and Forecasting of Equipment Failure Rate for the Electricity Distribution Network
In order to gain a deep understanding of planned maintenance, check the weaknesses of distribution network and detect unusual events, the network outage should be traced and monitored. On the other hand, the most important task of electric power distribution companies is to supply reliable and stable electricity with the minimum outage and standard voltage. This research intends to use time ser...
متن کاملStudy on the Characteristic Decomposition Components of DC SF6-Insulated Equipment under Positive DC Partial Discharge
Pulses with different amplitudes occur when an inner partial discharge fault exists in SF6-gas-insulated DC high-voltage electrical equipment. SF6 decomposes following complex physical and chemical processes. Discussing and quantifying the mathematical relationship of pulse discharge quantities to SF6 decomposition component characteristics is helpful to evaluate and predict the insulation faul...
متن کاملPreparation and Characterization of Cerium Doped Titanium Dioxide Nanoparticles by the Electrical Discharge Method
Titanium dioxide nanoparticles (TiO2) are known as a widely used photocatalyst. In order to improve the performance of these nanoparticles, the recombination of the electron-cavity pair must be reduced and the absorption rate of the visible region should be expanded. One way to increase the performance of these nanoparticles is using cerium doped TiO2. In the present study, pure and doped titan...
متن کاملStudy on Monitoring System for Partial Discharge of Electrical Equipment
The detection and fault identification of the partial discharge is the important aspect for the monitoring of the power equipment. For the lacks of the traditional detection methods, this paper analyzed the UHF signal characteristic parameters of the power equipment’s partial discharge, and developed the UHF detection system of the partial discharge. The A/D technology of the gain equalization ...
متن کاملThe effect of self-management based discharge planning on treatment adherence in patients with heart failure
Background & Aim: Patients with heart failure experience some outcomes such as poor self-management, poor adherence to treatment and low quality of life. The aim of the current study was to evaluate the effect of self-management based discharge planning on treatment adherence in patients with heart failure. Methods & Materials: In this quasi-experimental research, 80 patients with heart failur...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
ژورنال
عنوان ژورنال: Energy and Power Engineering
سال: 2009
ISSN: 1949-243X,1947-3818
DOI: 10.4236/epe.2009.12019