The response of CR-39 nuclear track detector to 1–9 MeV protons
نویسندگان
چکیده
منابع مشابه
The response of CR-39 nuclear track detector to 1-9 MeV protons.
The response of CR-39 nuclear track detector (TasTrak(®)) to protons in the energy range of 0.92-9.28 MeV has been studied. Previous studies of the CR-39 response to protons have been extended by examining the piece-to-piece variability in addition to the effects of etch time and etchant temperature; it is shown that the shape of the CR-39 response curve to protons can vary from piece-to-piece....
متن کاملA parameterization of nuclear track profiles in CR-39 detector
In this work, the empirical parameterization describing the alpha particles’ track depth in CR-39 detectors is extended to describe longitudinal track profiles against etching time for protons and alpha particles. MATLAB based software is developed for this purpose. The software calculates and plots the depth, diameter, range, residual range, saturation time, and etch rate versus etching time. ...
متن کاملProton beam dosimetry by CR-39 track-etched detector
Background: High and intermediate energy protons are not able to form a track in a solid state nuclear track detector (SSNTD) directly. However, such tracks can be formed through secondary particles created during primary radiation nuclear reactions in a SSNTD. Materials and Methods: The protons with primary energies of 9.6 and 30 MeV available at the cyclotron accelerator with corresponding lo...
متن کاملproton beam dosimetry by cr-39 track-etched detector
background: high and intermediate energy protons are not able to form a track in a solid state nuclear track detector (ssntd) directly. however, such tracks can be formed through secondary particles created during primary radiation nuclear reactions in a ssntd. materials and methods: the protons with primary energies of 9.6 and 30 mev available at the cyclotron accelerator with corresponding lo...
متن کاملImpact of x-ray dose on the response of CR-39 to 1-5.5 MeV alphas.
The CR-39 nuclear track detector is used in many nuclear diagnostics fielded at inertial confinement fusion (ICF) facilities. Large x-ray fluences generated by ICF experiments may impact the CR-39 response to incident charged particles. To determine the impact of x-ray exposure on the CR-39 response to alpha particles, a thick-target bremsstrahlung x-ray generator was used to expose CR-39 to va...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
ژورنال
عنوان ژورنال: Review of Scientific Instruments
سال: 2011
ISSN: 0034-6748,1089-7623
DOI: 10.1063/1.3653549