The residual electron density distribution in spinels
نویسندگان
چکیده
منابع مشابه
Electron-positron momentum density distribution in diamond
We have measured the momentum distribution of the electron-positron annihilating pair in diamond as a function of crystallographic orientation, using the Doppler broadening technique of positron annihilation spectroscopy. A 1% variation in the longitudinal projection of the momentum distribution was observed as the sample was rotated about the (110) axis. This anisotropic distribution shows an ...
متن کاملElectron Density Distribution in the Organic Superconductor (TMTSF)2AsF6.
Excellent crystals of (TMTSF)(2)AsF(6) (TMTSF, tetramethyltetraselenafulvalene) were employed to obtain x-ray diffraction data for a determination of the electron density distribution in this organic superconductor. Electron density was observed between molecules in a stack of donors of an organic metal and between certain interstack selenium atoms of these donors.
متن کاملElectron density distribution in paramagnetic chromium: A -ray diffraction study
High-accuracy single-crystal structure factors, complete up to sin / =1.78 Å−1 have been measured from paramagnetic chromium at 333 K using 316.5 keV radiation. A detailed description of the electron density distribution is derived in terms of a multipolar atomic deformation model. There is pronounced charge asphericity in the valence region arising from preferential occupancy of the t2g subshe...
متن کاملOn the effect of short-range magnetic ordering on electron energy-loss spectra in spinels
The energy-loss near-edge structure (ELNES) at the oxygen K edge in two AB2O4 spinels (A=Mg, B=Al,Cr) is reported. In MgAl2O4 the experimental data is successfully modelled within the LDA framework. In the case of MgCr2O4 spin-polarisation, in the form of antiferromagnetic ordering on the Cr sub-lattice, must be included despite the fact that the measurements were performed at approximately 30 ...
متن کاملTomographic Reconstruction of the Ionospheric Electron Density in term of Wavelets
Ionospheric tomography is a method to investigate the ionospheric electron density in two or three dimensions. In this study, the function-based tomographic technique has been used for regional reconstruction of a 3D tomographic model of the ionospheric electron density using the GPS measurements of the Iranian Permanent GPS Network. Two-dimensional Haar wavelets and empirical orthogonal functi...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
ژورنال
عنوان ژورنال: Nihon Kessho Gakkaishi
سال: 1995
ISSN: 0369-4585,1884-5576
DOI: 10.5940/jcrsj.37.supplement_74