THE REDUCTION OF METAL ARTIFACTS USING BAND PASS MEDIAN FILTER ON HEAD CT SCAN

نویسندگان

چکیده

Background: One of the artifacts found on CT scan is a metal artifact. Metal are caused by objects present in patients’ bodies. The file can cover organ that will be evaluated, and it inferred with pixel value (CT number) assessment tissue around metal. Purpose: To determine effect band pass median filter find optimal to reduce head scan. Method: A total 43 samples patients’s files from CT-scan without any contrast were reconstructed using four filters obtained R1, R2, R5, R10 filters. Two radiology specialists assessed for reduction ImageJ application. Result: Four variations affected because maintained point was close its neighboring points different replacing grey level pixels. recommendation R1 has largest SNR (16.9773) smallest RMSE (8.57501) so result image more informative diagnostic value. Conclusion: reducing artifacts. Images substantial fractional values produced an still had

برای دانلود باید عضویت طلایی داشته باشید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

The Band Pass Filter

The `ideal' band pass ̄lter can be used to isolate the component of a time series that lies within a particular band of frequencies. However, applying this ̄lter requires a dataset of in ̄nite length. In practice, some sort of approximation is needed. Using projections, we derive approximations that are optimal when the time series representations underlying the raw data have a unit root, or are...

متن کامل

CT Filter with In - Band Noise Reduction

In a direct-conversion wireless receiver the baseband filter should be able to handle large blockers, resulting in a very challenging spurious free dynamic range (SFDR) requirement. In particular, the noise added in-band trades off with the linearity required to handle close out-of-band interferers [1]. Since the integrated noise generally is proportional to kT/C, once the noise floor for the f...

متن کامل

Thyroid dose and dose reduction method from CT scan of head and neck

Introduction: Computed tomography (CT) consists of 11% of all imaging methods, but accounts for approximately 67% of radiation exposure due to diagnostic cases. More than one-third of all CT scans are done in the head and neck area. The thyroid gland is irradiated during CT head and neck. According to studies, this gland has the highest levels of radiation-induced cancer, and i...

متن کامل

the effect of consciousness raising (c-r) on the reduction of translational errors: a case study

در دوره های آموزش ترجمه استادان بیشتر سعی دارند دانشجویان را با انواع متون آشنا سازند، درحالی که کمتر به خطاهای مکرر آنان در متن ترجمه شده می پردازند. اهمیت تحقیق حاضر مبنی بر ارتکاب مکرر خطاهای ترجمانی حتی بعد از گذراندن دوره های تخصصی ترجمه از سوی دانشجویان است. هدف از آن تاکید بر خطاهای رایج میان دانشجویان مترجمی و کاهش این خطاها با افزایش آگاهی و هوشیاری دانشجویان از بروز آنها است.از آنجا ک...

15 صفحه اول

Performance & Analysis of Blocking Artifacts Reduction Using Guassian Adaptive Spatial Low Pass Filter

Ringing artifacts that appear as spurious signal near sharp transitions in a signal appear as ghosts (or) near edges. Two techniques called LPF and ASLPF is used. LPF is used for only just identifying the artifacts present in the video image. ASLPF (Adaptive Spatial Low Pass Filter) is used to identify the artifacts whether it is present in horizontal (or) vertical position (or) near edges. DCT...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

ژورنال

عنوان ژورنال: Journal of vocational health studies

سال: 2022

ISSN: ['2580-7161', '2580-717X']

DOI: https://doi.org/10.20473/jvhs.v6.i1.2022.17-23