The Reasons for Discrepancies in Target Volume Delineation
نویسندگان
چکیده
منابع مشابه
Optimization of clinical target volume delineation using magnetic resonance spectroscopic imaging (MRSI) in 3D conformal radiotherapy of prostate cancer
Background: For the purpose of individual clinical target volume assessment in radiotherapy of prostate cancer, MRSI was used as a molecular imaging modality with MRI and CT images. Materials and Methods: The images of 20 prostate cancer patients were used in this study. The MR and MRSI images were registered with CT ones using non-rigid registration technique. The CT based planning (BP), CT/MR...
متن کاملRobust optimization of dose-volume metrics for prostate HDR-brachytherapy incorporating target volume delineation uncertainties
In radiation therapy planning, uncertainties in target volume definition yield a risk of underdosing the tumor. The classical way to prevent this in the context of external beam radiotherapy (EBRT) has been to expand the clinical target volume (CTV) with an isotropic margin to obtain the planning target volume (PTV). However, the EBRT-based PTV concept is not directly applicable to brachytherap...
متن کاملthe search for the self in becketts theatre: waiting for godot and endgame
this thesis is based upon the works of samuel beckett. one of the greatest writers of contemporary literature. here, i have tried to focus on one of the main themes in becketts works: the search for the real "me" or the real self, which is not only a problem to be solved for beckett man but also for each of us. i have tried to show becketts techniques in approaching this unattainable goal, base...
15 صفحه اولThe Role of MRSI in Target Volume Definition for Radiation Therapy of Prostate Cancer
Introduction: Recently, magnetic resonance spectroscopic imaging (MRSI), as a functional imaging method, has been used for clinical target volume definition. In this study, we used this method to define the target volume in prostate radiotherapy. Material and Method: In this study, we used images of 20 prostate cancer cases. MRSI and MRI images were fused with CT images. Then, treatment plannin...
متن کاملPostoperative Radiotherapy for Glioma: Improved Delineation of the Clinical Target Volume Using the Geodesic Distance Calculation
OBJECTS To introduce a new method for generating the clinical target volume (CTV) from gross tumor volume (GTV) using the geodesic distance calculation for glioma. METHODS One glioblastoma patient was enrolled. The GTV and natural barriers were contoured on each slice of the computer tomography (CT) simulation images. Then, a graphic processing unit based on a parallel Euclidean distance tran...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
ژورنال
عنوان ژورنال: Strahlentherapie und Onkologie
سال: 2006
ISSN: 0179-7158,1439-099X
DOI: 10.1007/s00066-006-1463-6