The P50 value detected by the oxygenation-dissociation analyser and blood gas analyser
نویسندگان
چکیده
منابع مشابه
Assessing the ABL 500 blood gas analyser
The ABL 500 blood gas analyser from Radiometer has cordless electrodes and does not use a humidifier for calibrating gases. During the evaluation of the analytical performance of this instrument, the problem of p0(2) accuracy was approached by comparing the values obtained with two kinds of tonometry (film and bubble). An acceptable level of imprecision was demonstrated for all measured paramet...
متن کاملAccuracy of the i-STAT bedside blood gas analyser.
The performance of the i-STAT portable clinical analyser for measuring blood gases and pH was evaluated with reference to a conventional blood gas analyser (ABL520 Radiometer). Ninety-two samples from the routine blood gas analysis laboratory were chosen according to a wide distribution of partial pressure of carbon dioxide (Pa,CO2), partial pressure oxygen (Pa,O2) and pH and then analysed. All...
متن کاملAgreement between an arterial blood gas analyser and a venous blood analyser in the measurement of potassium in patients in cardiac arrest.
BACKGROUND AND OBJECTIVE Rapid measurement of potassium is crucial in the resuscitation of patients in cardiac arrest. This is often done on an arterial blood gas sample taken during resuscitation and analysed in an emergency department based blood gas analyser. No-one has assessed how accurate or reliable this is when compared with the traditional method of sending a venous sample to the labor...
متن کاملThe CL-Atse Protocol Analyser
This paper presents an overview of the CL-Atse tool, an efficient and versatile automatic analyser for the security of cryptographic protocols. CL-Atse takes as input a protocol specified as a set of rewriting rules (IF format, produced by the AVISPA compiler), and uses rewriting and constraint solving techniques to model all reachable states of the participants and decide if an attack exists w...
متن کاملDependency Analyser Configurable by Measures
In this paper we present a dependency analyser able to compute syntax recognition and analysis according to dependency grammars. Analyser is able to deal with nonprojective constructions, it has means to express the level of word-order freedom and its limitations. Level of word-order freedom and level of robustness (correctness) of sentences can be given as parameters of the analysis. Data and ...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
ژورنال
عنوان ژورنال: Artificial Cells, Nanomedicine, and Biotechnology
سال: 2020
ISSN: 2169-1401,2169-141X
DOI: 10.1080/21691401.2020.1770272