The Newmarket pump: a new suction pump for external negative pressure ventilation.

نویسندگان
چکیده

برای دانلود باید عضویت طلایی داشته باشید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

The Newmarket pump: a new suction pump for external negative pressure ventilation.

A new electronically controlled pump has been developed for use with a cuirass in providing external negative pressure ventilation. It is smaller, lighter, and more versatile than currently available pumps and operates on a servo principle. A rotary valve between the pump and the cuirass varies the rate of extraction of air from the cuirass. The pressure within the cuirass is sensed by a pressu...

متن کامل

Choosing a negative pressure ventilation pump: are there any important differences?

Five negative pressure ventilator pumps were assessed to determine whether there were any differences in performance which were likely to be of clinical importance. The pumps tested were the NEV-100 (Lifecare Inc.), the Negavent Respirator DA-1 (Dima Italia), the Thompson Maxivent (Puritan Bennett), the CCP-001 and Newmarket pumps (Si-Plan Electronics Research Ltd). A patient model was employed...

متن کامل

A New Unique High-pressure Pump System

The combination of a 16 inch Pitot tube pump with a switched reluctance motor represents a significant development in the field of high-pressure pumping. A field proven Pitot tube pump design has been mechanically integrated with a high performance switched reluctance motor. The resulting system is approximately 40 percent of the size of the standard unit it replaces. The closecoupled pump elim...

متن کامل

Automatic Control of the Coronary Suction Pump

___________ _ (J. Extra-Corpor. Tech. 18[4) p.219-220 Winter 1986) A coronary suction device is described which affords the surgeon direct control of blood aspiration. The device described is nondisposable and can be made up from extra level sensors. With use of the device, there was a reduction in the time that coronary sucker pumps were used, hence reducing the aspiration of air. As the coron...

متن کامل

Impact of Impeller Stagger Angles on Pressure Fluctuation for a Double-Suction Centrifugal Pump

Pressure fluctuation may cause high amplitude of vibration of double‐suction centrifugal pumps, but the impact of impeller stagger angles is still not well understood. In this paper, pressure fluctuation experiments are carried out for five impeller configurations with different stagger angles by using the same test rig system. Results show that the stagger angles exert negligible effects on th...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

ژورنال

عنوان ژورنال: Thorax

سال: 1985

ISSN: 0040-6376

DOI: 10.1136/thx.40.9.677