The neutron facility at NCSR ‘Demokritos’ and neutron activation research activities of NTUA
نویسندگان
چکیده
Abstract At the 5.5 MV Tandem T11/25 Accelerator Laboratory of NCSR “Demokritos” quasi-monoenergetic neutron beams can be produced in energy ranges ∼15–21 MeV by means 3 H(d,n) 4 He reaction, ∼4–11 via 2 ∼2.0–5.3 using H(p,n) reaction and ∼120–650 keV 7 Li(p,n) Be reaction. The maximum flux has been determined to order $10^{5}\text{--}10^{6}\text{ n/cm}^{2}\text{s}$ 10 5 – 6 n/cm 2 s , implementing reference reactions, while variation beam is monitored a BF3 detector BC501A scintillator. have characterized multiple foil activation technique as well extensive simulations used for cross section measurements induced reactions again technique.
منابع مشابه
Shielding studies on a total-body neutron activation facility
Background: Prompt gamma neutron activation analysis (PGNAA) is known as a non-invasive technique capable of measuring elemental concentration in voluminous samples in a short period of time. Also it is a valuable diagnostic tool for total body elemental measurements. 252Cf and 241Am-Be sources which are usually used in this method, generate not only neutrons, but also emit high-energy and unwa...
متن کاملshielding studies on a total-body neutron activation facility
background: prompt gamma neutron activation analysis (pgnaa) is known as a non-invasive technique capable of measuring elemental concentration in voluminous samples in a short period of time. also it is a valuable diagnostic tool for total body elemental measurements. 252cf and 241am-be sources which are usually used in this method, generate not only neutrons, but also emit high-energy and unwa...
متن کاملFacilities for Fundamental Neutron Physics Research at the NIST Cold Neutron Research Facility
The features of two fundamental neutron physics research stations at the NIST cold neutron research facility are described in some detail. A list of proposed initial experimental programs for these two stations is also given.
متن کاملNeutron activation diagnostics at the National Ignition Facility (invited).
Neutron yields are measured at the National Ignition Facility (NIF) by an extensive suite of neutron activation diagnostics. Neutrons interact with materials whose reaction cross sections threshold just below the fusion neutron production energy, providing an accurate measure of primary unscattered neutrons without contribution from lower-energy scattered neutrons. Indium samples are mounted on...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
ژورنال
عنوان ژورنال: EPJ Techniques and Instrumentation
سال: 2023
ISSN: ['2195-7045']
DOI: https://doi.org/10.1140/epjti/s40485-023-00091-8