The NBS Proposal for a One GeV CW Racetrack Microtron Facility
نویسندگان
چکیده
منابع مشابه
A Novel Racetrack Microtron Accelerating Structure
We have designed, constructed, and evaluated a Rectangular Cavities Biperiodic Structure prototype for our compact 70 MeV pulsed RaceTrack Microtron [1]. We present here the design details and test measurements.
متن کاملThe Racetrack Microtron as a Negative Pion Source for Radiotherapy
Should clinical trials indicate that negative pion therapy is an improvement over present radiotherapy techniques, reliable pion sources of acceptable cost and size will be required at a number of major medical centers. A 300 KW, 500 MeV electron racetrack microtron is proposed which employs conventionalaccelerator guides andwhich can meet hospital requirements oncost, space and operalional rel...
متن کاملSimulations of Racetrack Microtron for Acceleration of Picosecond Electron Pulse
Low emittance sub-picosecond electron pulses are expected to be used in a wide field, such as free electron laser, laser acceleration, femtosecond X-ray generation by inverse Compton scattering, and pulse radiolysis, etc. In order to produce the low emittance sub-picosecond electron pulses, we are developing a compact racetrack microtron (RTM) with a new 5 MeV injection system adopting an laser...
متن کاملThe new 1 . 5 GeV Harmonic Double - Sided Microtron
In February 2007, the fourth stage of the Mainz Microtron, MAMI-C, started operations with a first experiment. The new Harmonic Double-Sided Microtron delivers an electron beam with energies up to 1.5GeV while preserving the excellent beam quality of the previous stages. The experimental program at MAMI is focused on studies of the hadron structure in the domain of non-perturbative QCD. In this...
متن کاملDaily dosimetric quality control of the MM50 Racetrack Microtron using an electronic portal imaging device.
The MM50 Racetrack Microtron, suited for advanced three-dimensional conformal radiotherapy techniques, is a complex machine in various respects. Therefore, for a number of gantry angles, daily quality control of the absolute output and fluence profiles of the scanned beams are mandatory. For the applied photon beams, a fast method for these daily checks, based on dosimetric measurements with th...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
ژورنال
عنوان ژورنال: IEEE Transactions on Nuclear Science
سال: 1983
ISSN: 0018-9499,1558-1578
DOI: 10.1109/tns.1983.4336637