منابع مشابه
The new ATLAS TRT read-out system
The ATLAS TRT detector [1] is very demanding in terms of electronics performance because of the high occupancy of the detector. A new version of the full read-out system, including two new ASICs and the new back-end modules, has been designed and tested successfully at 40 MHz clock rate and high trigger rate on a detector prototype. A description of this system will be given, as well as test re...
متن کاملReadout Electronics of the Na62 Gigatracker System
A crucial detector of the NA62 experiment is the beam spectrometer named Gigatracker. It consists of three stations of hybrid silicon pixels sensors with 150 ps (rms) of time resolution and 100 μm (rms) of space resolution. In addition the system operates under a high radiation environment and a high density of particles (up to 1.5 MHz/mm in the centre and 0.8 1 GHz in total). To meet these req...
متن کاملThe anti-aliasing requirements for area and timing mesurements with the Fluorescence Detector read-out channel
This note calculates the requirements of the anti-aliasing filter for the read-out of the fluorescence detector of the AUGER experiment. The filter order and its cut-off frequency are related to the errors in area and timing reconstruction. 1 System transfert functions The Fluorescence Detector read-out channel consist of a current preamplifier followed by a low pass anti-aliasing filter and a ...
متن کاملThe anti-aliasing requirements for amplitude mesurements with the Fluorescence Detector read-out channel
This note calculates the requirements on the anti-aliasing filter for the read-out of the fluorescence detector of the AUGER experiment. The filter order and its cut-off frequency are related to the error in amplitude reconstruction. 1 System transfert functions The Fluorescence Detector read-out channel consist of a current preamplifier followed by a low pass anti-aliasing filter and a samplin...
متن کاملThe Trigger and DAQ system for the NA62 experiment
The main goal of the NA62 experiment is to measure the branching ratio of the K → πνν̄ decay, collecting O(100) events in two years of data taking. Efficient online selection of interesting events and loss-less readout at high rate will be key issues for such experiment. An integrated trigger and data acquisition system has been designed. Only the very first trigger stage will be implemented in ...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
ژورنال
عنوان ژورنال: Journal of Instrumentation
سال: 2010
ISSN: 1748-0221
DOI: 10.1088/1748-0221/5/12/c12053