The Modeling of Bubble Lift-Off Diameter in Vertical Subcooled Boiling Flow
نویسندگان
چکیده
Bubble lift-off diameter is characterized as the size of a bubble rising from wall, which vital in boundary condition heat transfer model and interfacial area transport equation. In this paper, mechanistic force analysis was conducted to explore predictive for vertical channel subcooled boiling flow. Specifically, component growth normal wall shear lift lead on surface. Through analysis, we found that arranged be related superheat, latent heat, liquid velocity, fluid properties, bulk subcooling, etc. To account contribution influencing factors, dimensionless correlated with parameters, including Prandtl number, Reynolds Jacob subcooling. The proposed correlation assessed according experimental data predictions showed good agreement data.
منابع مشابه
Modeling of Upward Subcooled Flow Boiling of Refrigerant-113 in a Vertical Annulus
In this paper, a modified two-fluid model has been adopted to simulate the process of upward vertical subcooled flow boiling of refrigerant R-113 in a vertical annular channel at low pressure. The modified model considers temperature dependent properties and saturation temperature variation and was validated against a number of published low-pressure subcooled boiling experiments. The results s...
متن کاملThe Effect of Linear Change of Tube Diameter on Subcooled Flow Boiling and Critical Heat Flux
One of the major industry problems is the flow boiling, where reaching to the critical heat flux (CHF) condition can lead to a temperature jump and damage of the systems. In the present study, the effects of a uniform change in tube diameter on subcooled flow boiling and CHF was numerically investigated. The Euler-Euler model was used to investigate the relationship between the two liquid and v...
متن کاملEvaluation of Exerting Force on the Heating Surface Due to Bubble Ebullition in Subcooled Flow Boiling
Vibration characteristics of subcooled flow boiling on thin and long structures such as a heating rod were recently investigated by the author. The results show that the intensity of the subcooled boiling-induced vibration (SBIV) was influenced strongly by the conditions of the subcooling temperature, linear power density and flow velocity. Implosive bubble formation and collapse are the main n...
متن کاملInstability of subcooled boiling film on a vertical wall
Consider a vertical plate with a leading edge. The temperature of the plate is above the spontaneous nucleation temperature, so that vapor completely covers the plate. Two-dimensional quasi-parallel theory is used to examine the stability of the two-phase system. Numerical calculations show that the main parameter determining the thickness of the vapor film and its stability is the difference b...
متن کاملDevelopment of Two-phase Flow Cfd Code (eagle) with Interfacial Area Transport Equation for Analysis of Subcooled Boiling Flow
The interfacial area transport equation for a subcooled boiling flow is developed with a mechanistic model for the wall boiling source term. It includes the bubble lift-off diameter model and the lift-off frequency reduction factor model. Those models take into account a bubble’s sliding on the heated wall after a departure from the nucleate site and the coalescences of sliding bubbles. To impl...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
ژورنال
عنوان ژورنال: Energies
سال: 2022
ISSN: ['1996-1073']
DOI: https://doi.org/10.3390/en15186857