The Melting Point and the Density of Neptunium Metal. A Micro Melting Point Apparatus for Metals1

نویسندگان
چکیده

برای دانلود باید عضویت طلایی داشته باشید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

A melting-point-of gallium apparatus for thermometer calibration.

We have investigated the equilibrium melting point of gallium as a temperature fixed-point at which to calibrate small thermistor thermometers, such as those used to measure temperature in enzyme reaction analysis and other temperature-dependent biological assays. We have determined that the melting temperature of "6N" (99.999% pure) gallium is 29.770 +/- 0.002 degrees C, and that the constant-...

متن کامل

Melting Point Determination

An improved technique is described for the accurate determination of melting points of metals in the temperature range 1500° to 2500°C. The improvements consist of gradient heating and refinements in cavity preparation to obtain true black-body conditions. The melting point of hafnium, as determined by this method, is set a t 22220-+30°C. This is over 200°C higher than one of the values reporte...

متن کامل

Fabrication and Optimization of a PAGATA Gel Dosimeter: Increasing the Melting Point of the PAGAT Gel Dosimeter with Agarose Additive

Introduction: The PAGAT polymer gel dosimeter melts at 30 ˚C and even at room temperature during the summer, so it needs to be kept in a cool place such as a refrigerator. To increase the stability of the PAGAT gel, different amounts of agarose were added to the PAGAT gel composition and the PAGATA gel was manufactured. Material and Methods: The PAGATA gel vials were irradiated using a Co-60 ma...

متن کامل

Solid clusters above the bulk melting point

The fact that the melting points of nanoparticles are always lower than those of the corresponding bulk material is a paradigm supported by extensive experimental data for a large number of systems and by numerous calculations. Here we demonstrate that tin cluster ions with 10-30 atoms remain solid at approximately 50 K above the melting point of bulk tin. This behavior is possibly related to t...

متن کامل

A Melting Point for the Birefringent Component of Muscle

The A filament of the striated muscle sarcomere is an ordered aggregate of one or a few species of proteins. Ordering of these filaments into a parallel array is the basis of birefringence in the A region, and loss of birefringence is therefore a measure of decreased order. Heating caused a large decrease in the birefringence of glycerinated rabbit psoas muscle fibers over a narrow temperature ...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

ژورنال

عنوان ژورنال: Journal of the American Chemical Society

سال: 1951

ISSN: 0002-7863,1520-5126

DOI: 10.1021/ja01151a117