The DAΦNE Luminosity Monitor
DAΦNE, the Frascati Φ-factory, is an e+/e– collider with 2 interaction points (IPs). The center of mass energy is 1020 MeV and the design luminosity 4.2 × 1030 cm–2 s–1 in single bunch mode and 5 × 1032 cm–2 s–1 in multibunch mode. Between the possible electromagnetic reactions at the interaction point, single bremsstrahlung (SB) has been selected for the luminosity measurement. The SB high cou...
متن کاملThe MICE luminosity monitor
The MICE experiment will provide the first measurement of ionisation cooling, a technique suitable for reducing the transverse emittance of a tertiary muon beam in a future neutrino factory accelerator facility. MICE is presently in the final stages of commissioning its beam line. The MICE luminosity monitor has proved an invaluable tool throughout this process, providing independent measuremen...
متن کاملThe ATLAS Inner Detector
A DESCRIPTION OF THE ATLAS detector is given in the previous article by George Trilling. Twenty-eight U.S. universities and three national laboratories comprise about 20 percent of the ATLAS (A Toroidal LHC ApparatuS) collaboration, the largest single national group. U.S. physicists are involved in essentially all aspects of the ATLAS experiment, but I will only describe here one area of activi...
متن کاملThe ATLAS pixel detector
After a ten years planning and construction phase, the ATLAS pixel detector is nearing its completion and is scheduled to be integrated into the ATLAS detector to take data with the first LHC collisions in 2007. An overview of the construction is presented with particular emphasis on some of the major and most recent problems encountered and solved.
متن کاملValidation Studies of the ATLAS Pixel Detector Control System
The ATLAS pixel detector consists of 1744 identical silicon pixel modules arranged in three barrel layers providing coverage for the central region, and three disk layers on either side of the primary interaction point providing coverage of the forward regions. Once deployed into the experiment, the detector will employ optical data transfer, with the requisite powering being provided by a comp...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
ژورنال
عنوان ژورنال: Nuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment
سال: 2016
ISSN: 0168-9002
DOI: 10.1016/j.nima.2015.11.134