The LHCb RICH silica aerogel performance with LHC data
نویسندگان
چکیده
منابع مشابه
Performance of the LHCb RICH detector at the LHC
The LHCb experiment has been taking data at the Large Hadron Collider (LHC) at CERN since the end of 2009. One of its key detector components is the Ring-Imaging Cherenkov (RICH) system. This provides charged particle identification over a wide momentum range, from 2-100 GeV/c. The operation and control, software, and online monitoring of the RICH system are described. The particle identificati...
متن کاملAbsolute luminosity measurements with the LHCb detector at the LHC
Absolute luminosity measurements are of general interest for colliding-beam experiments at storage rings. These measurements are necessary to determine the absolute cross-sections of reaction processes and are valuable to quantify the performance of the accelerator. Using data taken in 2010, LHCb has applied two methods to determine the absolute scale of its luminosity measurements for proton-p...
متن کاملParticle identification at LHC: Alice and LHCb
The Alice and LHCb collaborations equipped their detectors with many technologies to identify particles in a large momentum range, both in the barrel and the forward regions. The methods used are described and some details on the hardware implementation are given. A few physics results illustrate the performances obtained by the two detectors.
متن کاملPerformance of the LHCb Detector during 2010-2011 data taking
The status and performance of the LHCb detector during the physics LHC physics run is described. The LHCb detector has a number of notable features including: 12 micron resolution in the transverse plane on 30-35 track primary vertices, pion and kaon separation from 1 to 100 GeV, and 1 MHz full readout of all subsystems. The detector is being operating above its design luminosity and is compris...
متن کاملPreparation and Characterization of Silica Aerogel Microspheres
Silica aerogel microspheres based on alkali silica sol were synthesized using the emulsion method. The experimental results revealed that the silica aerogel microspheres (4-20 µm in diameter) were mesoporous solids with an average pore diameter ranging from 6 to 35 nm. The tapping densities and specific surface areas of the aerogel microspheres are in the range of 0.112-0.287 g/cm³ and 207.5-66...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
ژورنال
عنوان ژورنال: Nuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment
سال: 2011
ISSN: 0168-9002
DOI: 10.1016/j.nima.2010.09.119