The Interaction between Polymer Thin Films and Positron from Slow Positron Beam
نویسندگان
چکیده
منابع مشابه
Porosity of Low-κ Materials Studied by Slow Positron Beam
Until the past few years, aluminium was used in semiconductor technology as interconnect metal and silicon dioxide (SiO2, κ = 3.9) as the interand intra-level insulator. With the demand of scaling the dimension of advanced integrated circuits well below the 100 nm DRAM 1/2 pitch technology node [1], the signal delay (resistance–capacitance RC delay) becomes one limitation in increasing the spee...
متن کاملProbing slow dynamics in supported thin polymer films.
We have used variable cooling rate ellipsometric measurements to probe the slow dynamics in thin supported polystyrene films. For the slowest cooling rates (approximately 1 K/min) the measured Tg values are reduced below the bulk value with the measured Tg of 341 K for a 6 nm film. As the cooling rate is increased the Tg reductions become smaller until at cooling rates >90 K/min there is only s...
متن کاملA New Ultra - Cold Positron Beam and Applications To Low - Energy Positron Scattering and Electron - Positron Plasmas
OF THE DISSERTATION A New Ultra-Cold Positron Beam and Applications To Low-Energy Positron Scattering and Electron-Positron Plasmas
متن کاملAsymmetric electrostatic and hydrophobic-hydrophilic interaction forces between mica surfaces and silicone polymer thin films.
We have synthesized model hydrophobic silicone thin films on gold surfaces by a two-step covalent grafting procedure. An amino-functionalized gold surface reacts with monoepoxy-terminated polydimethylsiloxane (PDMS) via a click reaction, resulting in a covalently attached nanoscale thin film of PDMS, and the click chemistry synthesis route provides great selectivity, reproducibility, and stabil...
متن کاملTarget chamber for a slow positron beam: optimization of count rate and minimization of backscattering effects
Positrons, which scatter back from the target and annihilate in chamber walls near the detectors, may cause a significant error in annihilation parameters. We have constructed a new UHV target chamber for slow positron beam studies. In our design special care has been taken to reduce the effect of backscattered positrons. Detector wells are designed for two-detector coincidence measurements and...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
ژورنال
عنوان ژورنال: Journal of Photopolymer Science and Technology
سال: 2003
ISSN: 0914-9244,1349-6336
DOI: 10.2494/photopolymer.16.411