The initial stability of uncemented acetabular components

نویسندگان
چکیده

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Polyethylene wear in uncemented acetabular components.

We measured polyethylene wear in 231 porous-coated uncemented acetabular cups. We divided the hips into two groups according to the fixation of the femoral component, by cementing (n = 97) or press-fit (n = 134). Follow-up was from three to five years. The patients in two sub-groups were matched for weight, diagnosis, sex, age and length of follow-up. The linear wear rate of cups articulated wi...

متن کامل

Catastrophic failure of the polyethylene liner of uncemented acetabular components.

Ten cases are described of catastrophic failure of the polyethylene liner of three different designs of uncemented acetabular component. Failure occurred as a result of either 'wearthrough' to the metal backing, liner fracture or a combination of both, at a mean of 4.6 years after implantation (2 to 7.6). At revision there was metallosis in all hips and osteolysis of the femur or the pelvis in ...

متن کامل

Backside volumetric change in the polyethylene of uncemented acetabular components.

Polyethylene wear of acetabular components is a key factor in the development of periprosthetic osteolysis and wear at the articular surface has been well documented and quantified, but fewer data are available about changes which occur at the backside of the liner. At revision surgery for loosening of the femoral component we retrieved 35 conventional modular acetabular liners of the same desi...

متن کامل

Primary stability of two uncemented acetabular components of different geometry: hemispherical or peripherally enhanced?

OBJECTIVE This study compared the primary stability of two commercially available acetabular components from the same manufacturer, which differ only in geometry; a hemispherical and a peripherally enhanced design (peripheral self-locking (PSL)). The objective was to determine whether altered geometry resulted in better primary stability. METHODS Acetabular components were seated with 0.8 mm ...

متن کامل

The fate of revised uncemented acetabular components in patients with rheumatoid arthritis.

The results of patients with rheumatoid arthritis who had revision hip arthroplasty have been studied infrequently. The purpose of this study was to review the authors' clinical and radiographic experiences and outcomes with revision hip arthroplasty. Revision total hip arthroplasties were done on 28 patients (30 hips). All hips had morselized bone grafting and four hips had bulk allografts for...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

ژورنال

عنوان ژورنال: The Journal of Bone and Joint Surgery. British volume

سال: 1992

ISSN: 0301-620X,2044-5377

DOI: 10.1302/0301-620x.74b3.1587880