The Influence of Internal Heat Exchanger on the Performance of Transcritical CO2 Water Source Heat Pump Water Heater
نویسندگان
چکیده
منابع مشابه
Experimental Study on the Performance of Water Source Trans-Critical CO2 Heat Pump Water Heater
The effect of the discharge pressure on the performance of the trans-critical CO2 heat pump with a low gas-cooler outlet temperature is experimentally investigated on a test rig of water source heat-pump water heater. The optimal discharge pressure of the trans-critical CO2 heat pump is investigated under different external operation conditions. When the tap-water temperature is low, the charac...
متن کاملInfluence of Refrigerant Charge Amount and EEV Opening on the Performance of a Transcritical CO2 Heat Pump Water Heater
Besides compressor rotary speed and parameters of water flowing through gas cooler and evaporator, refrigerant charge amount and electronic expansion valve (EEV) opening are two important parameters that have significant effects on the performance of a transcritical CO2 heat pump system. In this study, the effects of refrigerant charge amount on the performance of a transcritical CO2 heat pump ...
متن کاملPerformance study on solar assisted heat pump water heater using CO2 in a transcritical cycle
This study reports the numerical analyses of a CO2 transcritical cycle on solar assisted heat pump water heating system in which evacuated tube U-pipe solar collector is utilized as an evaporator. This simulation model can predict operating characteristics for moderate meteorological conditions of North Dakota. The main purpose of this work is to simulate the overall performance of the heat pum...
متن کاملField Evaluation for Air-source Transcritical CO2 Heat Pump Water Heater with Optimal Pressure Control
Several optimal discharge pressure correlations for transcritical CO2 heat pump in literature have been discussed in this paper. Most of them are related to the ambient temperature, the evaporation temperature and the gas cooler outlet temperature. A revised optimal discharge pressure model as the function of ambient temperature and water outlet temperature is developed based on earlier experim...
متن کاملEffect of Internal Heat Exchanger on Performance of Transcritical CO2 Systems with Ejector
The objective of this paper is to explore whether the use of an internal heat exchanger can further improve the performance of transcritical ejector systems with C02 as the working fluid. Instead of using a simplified thermodynamic cycle analysis, the approach taken here is based on a more elaborated and experimentally validated system model for a real mobile air-conditioning system for a typic...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
ژورنال
عنوان ژورنال: Energies
سال: 2020
ISSN: 1996-1073
DOI: 10.3390/en13071787