The impact of flattening-filter-free beam technology on 3D conformal RT
نویسندگان
چکیده
منابع مشابه
The impact of flattening-filter-free beam technology on 3D conformal RT
BACKGROUND The removal of the flattening filter (FF) leads to non-uniform fluence distribution with a considerable increase in dose rate. It is possible to adapt FFF beams (flattening-filter-free) in 3D conformal radiation therapy (3D CRT) by using field in field techniques (FiF). The aim of this retrospective study is to clarify whether the quality of 3D CRT plans is influenced by the use of F...
متن کاملStudy of Dosimetric Properties of Flattening Filter Free Photon Beam Passing through Cadmium Free Compensator Alloy
Background: This study aims to investigate radiation beam geometry of Cyberknife beam and change in dosimetric characteristics of six megavoltage (6MV) flattening filter free (FFF) beam after passing through high density cadmium free compensator alloy.Material and Methods: In this experimental study, changes in FFF beam dosimetric characteristics after passing through compensator alloy wa...
متن کاملConformal Flattening ITK Filter Release 0
This paper describes the Insight Toolkit (ITK) Conformal Flattening filter: itkConformalFlatteningFilter. This ITK filter is an implementation of a paper by Sigurd Angenent, et al., “On the Laplace-Beltrami Operator and Brain Surface Flattening” [1]. This filter performs an angle preserving map of any genus zero (i.e. no handles) surface to the sphere or, alternatively, to the plane. In this pa...
متن کاملInvestigation of Neutron Contamination of Flattening Filter and Flattening Filter-Free 10-MV Photon Beams in Elekta InfinityTM Accelerator
Introduction: This study aimed to measure the neutron contamination of flattening filter (FF) and flattening filter-free (FFF) 10-MV photon beams delivered by the Elekta InfinityTM accelerator. Material and Methods: The photoneutron spectrum produced by the Linac head was evaluated using a Monte Carlo (MC) simulation. The geometry ...
متن کاملOn flattening filter‐free portal dosimetry
Varian introduced (in 2010) the option of removing the flattening filter (FF) in their C-Arm linacs for intensity-modulated treatments. This mode, called flattening filter-free (FFF), offers the advantage of a greater dose rate. Varian's "Portal Dosimetry" is an electronic portal imager device (EPID)-based tool for IMRT verification. This tool lacks the capability of verifying flattening filter...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
ژورنال
عنوان ژورنال: Radiation Oncology
سال: 2013
ISSN: 1748-717X
DOI: 10.1186/1748-717x-8-133