منابع مشابه
Readout Electronics of the Na62 Gigatracker System
A crucial detector of the NA62 experiment is the beam spectrometer named Gigatracker. It consists of three stations of hybrid silicon pixels sensors with 150 ps (rms) of time resolution and 100 μm (rms) of space resolution. In addition the system operates under a high radiation environment and a high density of particles (up to 1.5 MHz/mm in the centre and 0.8 1 GHz in total). To meet these req...
متن کاملInstruction - Based Learning for Mobile Robots ( IBL )
1. Background The IBL project was a collaboration between the School of Computing at the University of Plymouth and the Institute for Communicating and Collaborative Systems at the University of Edinburgh (Dr. Ewan Klein, separately funded under GR/M90160). The aim of the project was to explore the possibility for naïve human users of an assistant robot to instruct the robot on how to perform a...
متن کاملPerformance Evaluation of the ATLAS IBL Calibration
[email protected] or visit http://www.ziti.uni-heidelberg.de Figure 2: Scan results before and after tuning to a threshold of 2500 eand TOT target value 8. Histograms on top display the threshold distribution, 2D maps of the modules on the bottom show TOT values for a MIP charge deposit. Data are for one module consisting of two FE-I4 frontend chips. Scans were run in the SR1 ...
متن کاملThe electronic readout of the CMS tracking system
A description is given of the electronic readout system proposed by the CMS experiment for the microstrip tracker. It is an analogue system based on a front end chip development by RD20 and analogue optical links being developed by RD23. Both gas and silicon microstrips are read out by the same system with minor modifications to the front end chips to accommodate the different detector characte...
متن کاملTesla Test Facility Stripline Readout System
The elaboration of the signals provided by the fourstripline Beam Position Monitors (BPM) on the superconducting linac TTF will be accomplished by parallel rf circuits, giving a signal of ~1 V /cm, indipendent of beam current, for both horizontal and vertical beam positions with time response ~1μs. and useful range > ±1 cm The performances with respect to thermal drifts and input dynamics are p...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
ژورنال
عنوان ژورنال: Journal of Instrumentation
سال: 2011
ISSN: 1748-0221
DOI: 10.1088/1748-0221/6/01/c01006